CX2550/60/70 M4
Upgrade and Maintenance Manual
303
System board and components
9.5.4
Replacing the microSD card
9.5.4.1
Preliminary steps
Ê
"Locating the defective server" on page 45
Ê
"Shutting down the server node" on page 50
Ê
If applicable, remove all external cables from the server node.
Ê
"Removing the server node from the server enclosure" on page 51
Ê
"Removing the memory slot air duct (Air cooling only)" on page 63
9.5.4.2
Replacing the microSD card
Ê
Remove the Dual microSD 64GB Enterprise, see section
Dual microSD 64GB Enterprise" on page 300
Ê
Remove the defective microSD card from the Dual microSD 64GB
Enterprise. Proceed as described in the following:
Ê
To eject the defective microSD card, gently push it in and then let go (see
figure
).
Ê
Pull the microSD card straight out of its slot.
V
CAUTION!
The microSD card contains customer information. After replacing the
microSD card, hand the defective card over to the customer. If the
customer requests disposal of the defective microSD card, proceed
as follows:
Ê
Using a pair of side-cutting pliers, cut the microSD card in half.
Ê
Install the new microSD card on the Dual microSD 64GB Enterprise.
Proceed as described in the following:
Ê
With the label facing up, insert the microSD card into the microSD slot on
the controller until it locks in place (see figure
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools:
a pair of side-cutting pliers
Summary of Contents for PRIMERGY CX2550 M4
Page 6: ...6 Upgrade and Maintenance Manual CX2550 60 70 M4 ...
Page 20: ...Upgrade and Maintenance Manual CX2550 60 70 M4 Contents ...
Page 46: ...46 Upgrade and Maintenance Manual CX2550 60 70 M4 Important information ...
Page 70: ...70 Upgrade and Maintenance Manual CX2550 60 70 M4 Basic hardware procedures ...
Page 114: ...114 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 182: ...182 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 192: ...192 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory Figure 85 Memory dummy module ...
Page 204: ...204 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory ...
Page 320: ...320 Upgrade and Maintenance Manual CX2550 60 70 M4 System board and components ...
Page 356: ...356 Upgrade and Maintenance Manual CX2550 60 70 M4 GPGPU extension tray ...
Page 418: ...418 Upgrade and Maintenance Manual CX2550 60 70 M4 SXM2 extension tray ...
Page 454: ...454 Upgrade and Maintenance Manual CX2550 60 70 M4 Appendix ...