226
Upgrade and Maintenance Manual
CX2550/60/70 M4
Processor (CPU)
Ê
For CPU 1 and CPU 2 LC heat sinks, loosen the captive screws (circles)
following the sequence described below:
V
CAUTION!
Please don’t use an electric screwdriver.
1. Loosen the four captive screws one by one (in the sequence 4 to 1)
rotating them a half-turn each.
2. Loosen the captive screws 4 and then 3 rotating them two or three turns
each.
3. Repeat the step 2 until the screws 4 and 3 are completely loosened.
4. Loosen the captive screws 2 and then 1 rotating them two or three turns
each.
5. Repeat the step 4 until the screws 2 and 1 are completely loosened.
I
There are different procedures of removing the flexible tubes for
CX2550 M4 / CX2560 M4 and CX2570 M4.
8.3.2.1
CPU / RAM loop type 1: Removing the flexible tubes (CX2550 M4
/ CX2560 M4) Type 1
Figure 116: Removing the LC metal plate
Ê
Remove the three screws (see circles).
Summary of Contents for PRIMERGY CX2550 M4
Page 6: ...6 Upgrade and Maintenance Manual CX2550 60 70 M4 ...
Page 20: ...Upgrade and Maintenance Manual CX2550 60 70 M4 Contents ...
Page 46: ...46 Upgrade and Maintenance Manual CX2550 60 70 M4 Important information ...
Page 70: ...70 Upgrade and Maintenance Manual CX2550 60 70 M4 Basic hardware procedures ...
Page 114: ...114 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 182: ...182 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 192: ...192 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory Figure 85 Memory dummy module ...
Page 204: ...204 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory ...
Page 320: ...320 Upgrade and Maintenance Manual CX2550 60 70 M4 System board and components ...
Page 356: ...356 Upgrade and Maintenance Manual CX2550 60 70 M4 GPGPU extension tray ...
Page 418: ...418 Upgrade and Maintenance Manual CX2550 60 70 M4 SXM2 extension tray ...
Page 454: ...454 Upgrade and Maintenance Manual CX2550 60 70 M4 Appendix ...