414
Upgrade and Maintenance Manual
CX2550/60/70 M4
SXM2 extension tray
11.7
Replacing the SMX2 base board
11.7.1 Preliminary steps
Perform the following procedures:
Ê
"Disabling the boot watchdog functionality of ServerView Operations
Manager" on page 73
Ê
Locate the desired server node with the ID button.
Ê
"Shutting down the server node" on page 50
Ê
If applicable, remove all external cables from the server node.
Ê
"Removing the server node from the server enclosure" on page 51
Ê
Remove all SXM2 heat sinks, see section
"Removing liquid cooling (LC)" on
.
Ê
Remove all SXM2 extensions, see section
.
Ê
"Removing the GPGPU / SXM2 extension tray" on page 53
Ê
Remove the SXM2 riser cards, see section
and
"Removing the SXM2 base board" on page 415
.
Field Replaceable Unit
(FRU)
Hardware: 45 minutes
Tools:
Preliminary and main steps: PH2 / (+) No. 2 screw
Summary of Contents for PRIMERGY CX2550 M4
Page 6: ...6 Upgrade and Maintenance Manual CX2550 60 70 M4 ...
Page 20: ...Upgrade and Maintenance Manual CX2550 60 70 M4 Contents ...
Page 46: ...46 Upgrade and Maintenance Manual CX2550 60 70 M4 Important information ...
Page 70: ...70 Upgrade and Maintenance Manual CX2550 60 70 M4 Basic hardware procedures ...
Page 114: ...114 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 182: ...182 Upgrade and Maintenance Manual CX2550 60 70 M4 Expansion cards and OCP mezzanine cards ...
Page 192: ...192 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory Figure 85 Memory dummy module ...
Page 204: ...204 Upgrade and Maintenance Manual CX2550 60 70 M4 Main memory ...
Page 320: ...320 Upgrade and Maintenance Manual CX2550 60 70 M4 System board and components ...
Page 356: ...356 Upgrade and Maintenance Manual CX2550 60 70 M4 GPGPU extension tray ...
Page 418: ...418 Upgrade and Maintenance Manual CX2550 60 70 M4 SXM2 extension tray ...
Page 454: ...454 Upgrade and Maintenance Manual CX2550 60 70 M4 Appendix ...