Command Specifications
4-34
C141-C012
Table 4.16 Combinations of error recovery flags (2/4)
EER
PER
DTE
DCR
Error Recovery Procedure
0
1
0
1
1. Rereading is tried repeatedly up to the number of times specified in the "Read
Retry Count", "Write Retry Count" or "Verify Retry Count" parameter. Data
correction is not executed according to the ECC.
2. When error recovery has succeeded, processing of the command is continued.
3. If unrecoverable errors have been detected, execution of that command is
terminated at that point.
4. Transfer of data in blocks which include unrecoverable errors to the INIT is
done in accordance with the specification in the TB bit (read commands).
5. When recovery from all detected errors has been successful, a CHECK
CONDITION status (RECOVERED ERROR [=1]) is reported after all
processing of the command is completed and the sense data indicate the
content of the last error that was successfully recovered from and the address
of the data block where that error occurred.
0
1
1
0
1. Rereading is tried repeatedly up to the number of times specified in the "Read
Retry Count", "Write Retry Count" or "Verify Retry Count" parameter. If
possible, data correction is executed afterward according to the ECC.
2. When error recovery has succeeded, or even when recovery is impossible,
execution of the command is terminated with a CHECK CONDITION status at
the point when error recovery processing is completed, and the sense data
indicate the data block address where that error occurred.
3. Transfer to the INIT of data in blocks with recovered errors is done, but
transfer to the INIT of data blocks in which the errors were unrecoverable is
done in accordance with the specification in the TB bit (read commands).
0
1
1
1
1. Rereading is tried repeatedly up to the number of times specified in the "Read
Retry Count", "Write Retry Count" or "Verify Retry Count" parameter. Data
correction is not executed according to the ECC.
2. When error recovery has succeeded, or even when recovery is impossible,
execution of the command is terminated with a CHECK CONDITION status at
the point when error recovery processing is completed, and the sense data
indicate the data block address where that error occurred.
3. Transfer to the INIT of data in blocks with recovered errors is done, but
transfer to the INIT of data blocks in which the errors were unrecoverable is
done in accordance with the specification in the TB bit (read commands).
Summary of Contents for MAX3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 368: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 396: ...This page is intentionally left blank ...
Page 398: ......
Page 399: ......
Page 400: ......