2.8 Command Processing Exceptions
C141-C012
2-15
The IDD terminates abnormally all commands and tasks (which are being
executed or are being queued) which it has already received from an overlapping
INIT and also terminates abnormally both the command or task that caused the
overlap, in the order described below.
1) If, during execution of a command received from an INIT, the IDD
terminates execution of the command. If the command is still in the queue
and has not yet been executed, the IDD clears that command.
2) The IDD reports the CHECK CONDITION status with for the command that
caused the overlap. The sense data generated by the IDD at this time shows
ABORTED COMMAND [= B]/Overlapped commands attempted [= 4E-00].
3) The IDD reports the OVERLAPPED TAG ATTEMPTED [=0A] response
with for the task that caused the overlap.
1) The INIT is permitted to sent an ABORT TASK, ABORT
TASK SET, CLEAR TASK SET, LOGICAL UNIT RESET, or
HARD RESET command, specifying the logical unit in order
to terminate processing of a command that is currently
disconnecting. (Shown in item 2.8.5.)
2) Overlapped command specifications are applicable without
dependence on the type of command that was issued second.
For example, even if the command that was issued second is an
INQUIRY or REQUEST SENSE command, the IDD reports
the CHECK CONDITION status and terminates both
commands abnormally.
2.8.2 Illegal LUN specification
The IDD supports only the logical unit number (LUN) LUN = 0. If a LUN other
than this is specified, the IDD operates in one of the following ways, depending
on the type of command that is issued at that time.
1) For an INQUIRY command, even if an invalid LUN is specified, the
command is executed normally. However, byte 0 of the “Standard INQUIRY
Data” transferred to the INIT by that command (the “Qualifier” field and the
“Device Type Code” field) shows X‘7F’.
2) If an invalid LUN is specified for any command other than the INQUIRY
command or the REQUEST SENSE command, that command is executed
normally.
Summary of Contents for MAX3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 368: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 396: ...This page is intentionally left blank ...
Page 398: ......
Page 399: ......
Page 400: ......