4.1 Control/Sense Commands
C141-C012
4-63
b. PHY OPERATION CODE
The operation code specified by SMP PHY CONTROL is set.
c. ATTACHED DEVICE TYPE
"001": Indicates that the device type is End device.
d. NEGOTIATE PHYSICAL LINK RATE
Indicates the physical link rate value that has been established through a
speed negotiation sequence.
"8": 1.5 Gbps
"9": 3.0 Gbps
e. ATTACHED SSP INITIATOR PORT
Indicates the SSP INIT value received from the INIT with an IDENTIFY
address frame.
f.
ATTACHED STP INITIATOR PORT
Indicates the STP INIT value received from the INIT with an IDENTIFY
address frame.
g. ATTACHED SMP INITIATOR PORT
Indicates the SMP INIT value received from the INIT with an IDENTIFY
address frame.
h. ATTACHED SSP TARGET PORT
Indicates the SSP TARGET value received from the INIT with an IDENTIFY
address frame.
i.
ATTACHED STP TARGET PORT
Indicates the STP TARGET value received from the INIT with an
IDENTIFY address frame.
j.
ATTACHED SMP TARGET PORT
Indicates the SMP TARGET value received from the INIT with an
IDENTIFY address frame.
k. SAS
ADDRESS
Indicates the Port SAS ADDRESS of the TARGET.
port SAS address (Port-A): 5CCC CCCX XXXX XXX 2
port SAS address (Port-B): 5CCC CCCX XXXX XXX 3
C:
Company
ID
X: Serial number for WWN
Summary of Contents for MAX3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 368: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 396: ...This page is intentionally left blank ...
Page 398: ......
Page 399: ......
Page 400: ......