4.3 Format Commands
C141-C012
4-167
If this command is terminated with a CHECK CONDITION status,
the additional sense code/additional sense code qualifier in the
sense data is other than “No defect spare location available [=32-
00], and a valid logical block address (other than X ‘FFFFFFFF’) is
displayed in the “Command inherent information” field, it is
necessary for the INIT to reissue this command by the following
procedure after executing recovery processing (shown in Section
5.2) in accordance with the contents of the sense data.
1. Delete the defect descriptors which precede the defect
descriptor that specifies the logical block address displayed in
the “Command inherent information” field of the sense data
from the defect descriptor list specified in this command, and
leave that defect descriptor in the list.
Logical block address that indicates the “Command inherent
information” field of the sense data.
XXXX
Defect Descriptor List
Delete
Figure 4.2 Correction of the defect descriptor
2. Change the “Defect List Length” in the header and add the new ”Defect
descriptor list” corrected in 1), then reissue the REASSIGN BLOCKS
command.
Summary of Contents for MAX3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 368: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 396: ...This page is intentionally left blank ...
Page 398: ......
Page 399: ......
Page 400: ......