Command Specifications
4-182
C141-C012
The Self-Test executes the following test segments in ascending order by number:
1. Buffer RAM test
2. Flash ROM test
3. Pre-SMART
test
4. Low Level Format test
5. Random seek test
6. Sequential seek test
7. Data compare test
8. Random read test
9. Sequential read test
10. SMART test
4.4.2 RECEIVE DIAGNOSTIC RESULTS (1C)
Bit
Byte
7 6 5 4 3 2 1 0
0 X‘1C’
1 0 0 0 0 0 0 0
PCV
2 0 0 0 0 0 0 0 0
3
Transfer Byte Length (MSB)
4
Transfer Byte Length (LSB)
5 0 0 0 0 0 0 0 0
This command transfers data (response data) which show the results of executing
the SEND DIAGNOSTIC command from the IDD to the INIT. The format and
content of response data are determined by the parameter list (page code)
specified by the INIT in the SEND DIAGNOSTIC command.
The “Transfer byte length” field in the CDB shows the maximum number of bytes of
response data that can be received by the INIT by this command. The IDD transfers
the number of bytes of data specified by this field or all the bytes of the effective
response data, whichever is smaller in length. Also, when zero is specified in this
field, this command is terminated without anything being transferred.
Summary of Contents for MAX3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 368: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 396: ...This page is intentionally left blank ...
Page 398: ......
Page 399: ......
Page 400: ......