4.1 Control/Sense Commands
C141-C012
4-53
(7) Control mode parameters (page code = 0A)
The page descriptor format of this MODE SELECT parameter is shown in Table
4.22.
Table 4.22 MODE SELECT parameters: control mode parameters
Bit
Byte
7 6 5 4 3 2 1 0
0
0 0 0 0 1 0 1 0
1
X‘0A’ (Page Length)
2 TST
(Reserved)
GLTSD
RLEC
Default 0 0 0 0 0 0 0 0
Variable 0 0 0 0 0 0 1 1
3
Queue Algorithm Qualifier
Reserved
Qerr
DQue
Default 0 0 0 0 0 0 0 0
Variable 1 1 1 1 0 1 1 1
4 Reserve
d
RAC Reserved SWP
RAERP
UAAER
P
EAERP
Default 0 0 0 0 0 0 0 0
Variable 0 0 0 0 0 0 0 0
5 X‘00’
(Reserved)
6-7
Ready Aer Holdoff Period
Default
X‘0000’
Variable
X‘0000’
8-9
Busy Timeout Period
Default
X‘0000’
Variable
X‘0000’
10-11
Extended Self-Test Completion Time
Default
X‘xxxx’
Variable
X‘0000’
The parameters defined on this page control the operations of the tagged queuing
function and statistical information function.
Summary of Contents for MAX3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 338: ...This page is intentionally left blank ...
Page 368: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 394: ...This page is intentionally left blank ...
Page 396: ...This page is intentionally left blank ...
Page 398: ......
Page 399: ......
Page 400: ......