4.2 Data Access Commands
C141-C009
4-143
4.2.7 SEEK (0B)
Bit
Byte
7 6 5 4 3 2 1 0
0 X‘0B’
1
0
0
0
Logical Block Address (MSB)
2
Logical Block Address
3
Logical Block Address (LSB)
4
0 0 0 0 0 0 0 0
5
0 0 0 0 0 0 0 0
This command executes a seek operation of the cylinder/track where the logical
data block specified in the "Logical block address" field in the CDB exists.
When disconnect processing is permitted, the IDD performs disconnect processing
after receiving the CDB. After that, the IDD executes reconnect processing at the
point when the seek operation is completed and reports the status.
When disconnect processing is not permitted, the IDD executes the seek operation
while still connected to the FC interface and when it is completed, reports the
status of this command.