4.1 Control/Sense Commands
C141-C009
4-57
•
Starting Boundary
This field is enabled by the MODE SENSE command. This field indicates
the beginning of the active notch or, if the active notch is zero, the beginning
of the logical unit (IDD).
•
Ending Boundary
This field is valid in the MODE SENSE command. This field indicates the
ending of the active notch or, if the active notch is zero, the ending of the
logical unit (IDD) (see Table 4.18).
•
Page Notch
This is a bit map which shows whether or not other mode pages are being
changed if the device is notched. The most significant bit of this field
corresponds to page code 3Fh and the least significant bit corresponds to
page code 00h. If it is specified, the IDD disregards this value.
(9) Port control parameter (page code = 19)
This page is used to set parameters concerning data transfer of the drive and
to refer to the current settings and maximum settings of these parameters.
Table 4.26 Port control parameter: Page 0 Format (Short Page Format)
Bit
Byte
7 6 5 4 3 2 1 0
0
PS
SPF
(0)
0 1 1 0 0 1
1
X ' 06 ' (Page Length)
2 Reserved
Ready
LED
PROTOCOL IDENTIFIER
Default
0 0 0 0 0 1 1 0
Variable
0 0 0 1 0 0 0 0
3 X‘00’
(Reserved)
4-5
I_T NEXUS LOSS TIME
Default
X ' 07D0 '
Variable
X ' FFFF '
6-7
INITIATOR RESPONSE TIMEOUT
Default
X ' 0000 '
Variable
X ' 0000 '
Summary of Contents for MAU3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 370: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 384: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 390: ...This page is intentionally left blank ...
Page 391: ......
Page 392: ......