4.1 Control/Sense Commands
C141-C009
4-63
(10) Power condition parameter (page code = 1A)
Table 4.29 Power condition parameter: Page 0 Format (Short Page Format)
Bit
Byte
7 6 5 4 3 2 1 0
0 (PS)*
0 0 1 1 0 1 0
1
X ' 0A ' (Page Length)
2
X ' 00 ' (Reserved)
3
Idle
Stanby
Default
0 0 0 0 0 0 0 0
Variable
0 0 0 0 0 0 1 1
3
X ' 00 ' (Reserved)
4-7
Idle Condition Timer
Default
X ' FFFF '
Variable
X ' FFFF '
8-11
Standby Condition Timer
Default
X ' FFFF '
Variable
X ' FFFF '
This page descriptor is used to set the time over which the power condition
state is transformed into the idle condition or standby condition state.
However, because the IDD does not support the above states, the parameter
cannot be set on this page.
a. Idle
Specifies whether to permit the IDD to enter the Idle condition when the IDD
does not receive a command within the time specified in the "Idle Condition
Timer" field.
The IDD disregards this setting and executes Power Save.
b. Idle Condition Timer
Specifies the time before the IDD enters the Idle condition. When the Idle bit
is "1", the IDD disregards the specified value and enters Power Save mode in
two seconds (x 14) fixed.
Summary of Contents for MAU3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 370: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 384: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 390: ...This page is intentionally left blank ...
Page 391: ......
Page 392: ......