4.1 Control/Sense Commands
C141-C009
4-109
•
Accounting date (page 0E, code 0002)
Table 4.73 Accounting date (page 0E, code 0002)
Bit
Byte
7 6 5 4 3 2 1 0
4
5
(MSB)
X'0002' (Parameter code)
(Accounting
Date)
(LSB)
DU DS TSD
ETC
TMC LBIN LP
6
0 0 0 0 0 0 0 1
7
X'06' (Parameter Length)
8 (MSB)
9
10
Accounting date Year (4 ASCII characters)
11 (LSB)
12
13
(MSB)
Accounting date week (2 ASCII characters)
(LSB)
The Accounting date specified by parameter code 0002h is a parameter that may
be savable using a LOG SELECT command to indicate when the device was
placed in service. If the parameter is not yet set or is not settable, the default
value placed in the parameter field shall be 6 ASCII blank characters (20h). The
field shall not be checked for validity by the device server.
•
Specified cycle count over device lifetime (page 0E, code 0003)
Table 4.74 Specified cycle count over device lifetime (page 0E, code 0003)
Bit
Byte
7 6 5 4 3 2 1 0
4
5
(MSB)
X'0003' (Parameter code)
(Specified Cycle Count Over Device Lifetime) (LSB)
DU DS TSD
ETC
TMC LBIN LP
6
0 1 0 0 0 0 1 1
7
X'04' (Parameter Length)
8 (MSB)
9
10
Specified Cycle Count Over Device Lifetime
(4-byte binary number)
11 (LSB)
Summary of Contents for MAU3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 370: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 384: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 390: ...This page is intentionally left blank ...
Page 391: ......
Page 392: ......