Command Specifications
4-172
C141-C009
a. Page code list
This parameter page specifies transfer of the “Page code” list of the parameter
page supported by the IDD in the SEND DIAGNOSTIC command and the
RECEIVE DIAGNOSTIC RESULTS command to the INIT. Table 4.112
shows the format of this parameter page. The page code list supported by the
IDD is transferred to the INIT by the RECEIVE DIAGNOSTIC RESULTS
command which is issued following the SEND DIAGNOSTIC command that
specifies this parameter page (shown in Section 4.4.2 (1) )
Table 4.112 SEND DIAGNOSTIC parameters: page code list
Bit
Byte
7 6 5 4 3 2 1 0
0
X ‘00’ (Page Code)
1 0 0 0 0 0 0 0 0
2
X ‘00’ (Page parameter length)
3
X ‘00’ (Page parameter length)
b. Logical/physical address conversion
This parameter page specifies conversion of the address information
expressed in either the “Logical Block Address,” “Physical Sector Address”
or “Byte Distance from the Index” format to another expression format.
Table 4.113 shows this parameter page format. The INIT can specify the
address information that should be converted in this parameter page of the
SEND DIAGNOSTIC command, and can read the conversion results by the
RECEIVE DIAGNOSTIC RESULTS command (see Section 4.4.2 (2)).
Summary of Contents for MAU3036RC SERIES
Page 4: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blank ...
Page 136: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 370: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 384: ...This page is intentionally left blank ...
Page 386: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 390: ...This page is intentionally left blank ...
Page 391: ......
Page 392: ......