C141-E039-01EN
4 - 24
Table 4.4
Error recovery procedure (4 of 4)
Recovery
method
Recovery processing procedure
24
1)
Issue the READ or READ EXTENDED command and read the data for the block
where the error occurred.
2)
Investigate the cause of the data not matching and perform data recovery processing
from the INIT.
25
Reissue the original command (Retry). It is desirable at this time to confirm the
operations of the other INITs.
26
1)
Issue the LOG SENSE command and read the "Current" values of the LOG
SELECT parameters.
2)
Search for any parameter values which exceed the threshold value or have reached
the maximum value, then issue the LOG SELECT command from the INIT and
perform resetting.
3)
Reissue the original command.
27
1)
Issue the INQUIRY command and read the operation mode information.
2)
If the parameter values are appropriate, reissue the original command.
Note
This error could also be caused by a UNIT ATTENTION condition being generated,
caused by a programming error of another INIT, so when the values in the
parameters read in ( are illegal, recovery method 2 should be performed, or the
operations of the other INITs should be confirmed.