C141-E039-01EN
3 - 116
Bit
Byte
7
6
5
4
3
2
1
0
0
Page Code
1
0
0
0
0
0
0
0
0
2
Page Parameter Length (MSB)
3
Page Parameter Length (LSB)
4
Parameter
n
Figure 3.25 SEND DIAGNOSTIC Command: Parameter List Configuration
•
Page Code
This field specifies the code which identifies the type of parameter page being transferred
from the INIT and the operation that should be executed. The parameter pages which can
be specified by the INIT and their functions are as shown below.
Page Code (Hex)
Function
00
Reports a list of the supported page codes.
40
Logical/Physical Address Conversion
•
Page Parameter Length
This field specifies the byte length of the page parameter after byte 4. The INIT must
specify the same value as the length specified for each of the parameter pages, which will
be explained later.
•
Page Parameter
This field specifies each of the inherent parameters in each page code. Depending on the
page code, this field may not be necessary (page parameter length = 0).
~
~
~
~
~
~
Header
Page
Paramete
r