Table 4.3
Sense data error classification (3 of 4)
K
*
C
*
Q
*
Outline of Error
L
*
Recovery Method
(See Table 4.4.)
5
20
00
Invalid command operation code
None
2
21
00
Logical block address out of range
24
00
Invalid field in CDB
25
00
Logical unit not supported
26
00
Invalid field in parameter list
2C
00
Command sequence error
There is an error in the command specification
contents.
5
3D
00
Invalid bits in IDENTIFY message
None
3
90
00
Initiator's SCSI ID not identified
An error was detected in the SCSI protocol in
the command execution sequence.
6
29
xx
Power on, reset, or BUS DEVICE RESET occurred
None
14
The IDD was initialized by a Power on,
RESET condition or BUS DEVICE RESET
message.
6
2A
01
Mode parameters changed
None
21
The MODE SELECT parameters were
changed by another INIT.
5C
00
RPL status changed
The RPL parameters were changed by another
INIT..
6
2A
02
Log parameters changed
None
16
The LOG SELECT parameters were changed
by another INIT.
6
2F
00
Commands cleared by another INIT
None
25
Commands were cleared by another INIT.
6
3F
00
Target operating conditions have been changed
None
27
The operation code was changed by another
INIT.
6
5B
01
Log exception (Threshold condition met)
None
26
The current cumulative value exceeded the
current threshold value.
02
Log count at maximum
The current cumulative value reached the
maximum value.
6
5C
01
Spindle synchronized
None
22
Rotational synchronization was completed.
*
K: Sense Key
C: Sense Code
Q: Sub-sense code
L: Logging Necessary? (shown in item 4.2.3)