C141-E039-01EN
4 - 6
Table 4.2
Sense and subsense codes (1 of 7)
C
*
Q
*
Name
Explanation
Sense
key
00
00
No additional sense
No specific sense code exists.
0
information.
Writing to a write protected area was attempted.
7
06
I/O process terminated
I/O was interrupted by the Terminated I/O Process message.
0
01
00
No index/sector signal
The target sector was not detected by the sector counter within
the specified time.
4
02
00
No seek complete
A seek operation or rezero seek operation was not completed
within the specified time.
4
03
00
Peripheral device write
fault
A write operation to the disk media was terminated abnormally.
• Off track during write.
1, 4
80
Peripheral device write
fault
A write operation to the disk media was terminated abnormally.
• Write current abnormality
4
81
Peripheral device write
fault
A write operation to the disk media was terminated abnormally.
• Index, Sector pulse detected during write.
4
82
Peripheral device write
fault
A write operation to the disk media was terminated abnormally.
• Servo mark not found detected during write.
4
83
Peripheral device write
fault
A write operation to the disk media was terminated abnormally.
• Servo cell detected was detected during write.
4
84
Peripheral device write
fault
A write operation to the disk media was terminated abnormally.
• Head IC control abnormality was detected.
4
04
00
Logical unit not ready,
cause not reportable
Disk drive is in an inaccessible state.
(The motor doesn't reach the specified rotational speed.
2
04
Logical unit not ready,
format in progress
The drive cannot be accessed since it is being formatted.
2
0C
01
Write error recovered with
auto reallocation
An error during write was recovered from successfully by auto
alternate block allocation processing. 1
1
02
Write error, auto
reallocation failed
Auto alternate allocation processing failed during write.
3, 4
10
00
ID CRC or ECC error
An error was detected in the ID area.
1, 3
11
00
Unrecovered read error
An unrecoverable error was detected during reading of the data
area.
3
04
Unrecovered read error,
auto reallocation failed
Auto alternate block allocation processing during a read
operation failed.
3
12
00
Sync Byte not found for
ID field
SB (Sync Byte) in the ID area cannot be detected.
1, 3
13
00
Sync Byte not found for
Data field
SB (Sync Byte) could not be detected in the Data area.
1, 3
14
01
Record not found
The target data block (sector) could not be detected.
3
15
01
Mechanical positioning
error
A seek error occurred in the drive.
1, 4
*
C: Sense Code, Q: Sub-sense Code