13.2.4. Installing optional kits
Remote controller cable modification
(1) Use a tool to cut off the terminal on the end of the remote controller cable, and then
remove the insulation from the cut end of the cable.
(2) Connect the remote controller cable and connecting cable.
(Supplied with wired remote controller.)
Important: Be sure to insulate the connection between the cables.
20 mm
Remote
controller cable
Remote
controller cable
Red
Red
White
White
Black
Black
Insulated
connection
Connector
30 mm
35
~
45
mm
150
~160
mm
Installing the wired remote controller terminal (sold separately)
Connect the wired remote controller terminal to the connector (CNC01) on the relay con
-
trol board.
Relay wire
Connector : CNC01
Wired remote controller cable
Rib
Installing the external connect kit terminal (sold separately)
Connect the wire of external input/output to the board of external connect kit.
(
EXTERNAL INPUT CONNECT TO NO. CNA01
EXTERNAL OUTPUT CONNECT TO NO. CNB01, CNB02
)
External
connect kit cable
Error Status Output
connector : CNB02 (Black connector)
Operation Status Output
connector : CNB01 (White connector)
Control Input
(Operation/Stop or Forced stop)
connector : CNA01 (White connector)
Rib
Fixing the wires
After connecting the terminals, thread the wires through the clasp and rib of the control box as
circled in the figure below.
Then fix the wires onto the control box with the provided cable tie.
Relay control board
Cable tie
13.2.5. Installing the control cover
(1)
Attach the control cover.
(2)
Attach the 2 screws.
13.2.6. Labelling
Paste the wiring label beside the label for schematic diagram inside the front panel.
13.2.7. Installing the front panel and intake grille
(See “9. FRONT PANEL REMOVAL AND INSTALLATION” and “9.2. Front panel installation”)
14. SELECTING THE REMOTE CONTROLLER SIGNAL CODE
When two or more air conditioners are installed in a room and the remote controller is op
-
erating an air conditioner other than the one you wish to set, change the signal code of the
remote controller to operate only the air conditioner you wish to set (4 selections possible).
When two or more air conditioners are installed in a room, please contact your retailer to
set the individual air conditioner signal codes.
Selecting the Remote Controller Signal Code
Use the following steps to select the signal code of the remote controller. (Note that the
air conditioner cannot receive a signal code if the air conditioner has not been set for the
signal code.)
(1) Press the START/STOP (
) button until only the clock
is displayed on the remote controller display.
(2) Press the MODE button for at least 5 seconds to display
the current signal code (initially set to
).
(3) Press the SET TEMP. ( / ) buttons to change the
signal code between
.
Match the code on the display to the air conditioner
signal code.
(4) Press the MODE button again to return to the clock
display. The signal code will be changed.
• If no buttons are pressed within 30 seconds after the signal code is displayed, the
system returns to the original clock display. In this case, start again from step 1.
• The air conditioner signal code is set to A prior to shipment.
15. FUNCTION SETTING
Perform the “FUNCTION SETTING” according to the installation conditions using the remote
controller.
CAUTION
• Confirm whether the wiring work for outdoor unit has been finished.
• Confirm that the cover for the electrical enclosure on the outdoor unit is in place.
• This procedure changes to the function settings used to control the indoor unit according
to the installation conditions. Incorrect settings can cause the indoor unit to malfunction.
• After the power is turned on, perform the “FUNCTION SETTING” according to the
installation conditions using the remote controller.
• The settings may be selected between the following two: Function Number or Setting
Value.
• Settings will not be changed if invalid numbers or setting values are selected.
• Refer to the installation manual enclosed with the remote control unit when the wired
remote control unit (option) is used.
Entering the Function Setting Mode
While pressing the POWERFUL button and SET TEMP. ( ) simultaneously, press the
RESET button to enter the function setting mode.
Selecting the Function Number and Setting Value
[Reverse cycle model]
(1) Press the TEMP. ( / ) buttons to select the func
-
tion number. (Press the 10
°C
HEAT button to switch
between the left and right digits.)
(2) Press the POWERFUL button to proceed to setting
value. (Press the POWERFUL button again to return to
the function number selection.)
(3) Press the TEMP. ( / ) buttons to select the setting
value. (Press the 10
°C
HEAT button to switch between
the left and right digits.)
(4) Press the MODE button, and START/STOP button, in
the order listed to confirm the settings.
(5) Press the RESET button to cancel the function setting
mode.
(6) After completing the FUNCTION SETTING, be sure to
turn off the power and turn it on again.
Function Number
Setting
Value
ASTG18KMCA_中型標準モデルLM系_R32_0724m.indd 10
2013/07/24 16:52:18
Summary of Contents for AOTG36LATT
Page 4: ...2008 11 20 3 31 12 330 900 1290 9 21 OUTDOOR UNIT unit mm 650 400 370 air flow ...
Page 30: ...1204G4067 ...
Page 34: ...Unit mm 2012 05 29 3 AOTG12LVCC OUTDOOR UNIT AOTG09LVCC 540 290 790 540 540 660 290 450 ...
Page 60: ...1205G4083 ...
Page 85: ...1307G4239 ...
Page 113: ......
Page 114: ...1 DESCRIPTION OF EACH CONTROL OPERATION WALL MOUNTED type INVERTER ...
Page 135: ......
Page 136: ...2 TROUBLE SHOOTING WALL MOUNTED type INVERTER ...
Page 169: ......
Page 170: ...3 APPENDING DATA WALL MOUNTED type INVERTER ...
Page 176: ...4 INSTALLATION WORK WALL MOUNTED type INVERTER ...
Page 181: ......
Page 187: ......
Page 188: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan September 2013 Printed in Japan ...
Page 190: ...1 INDOOR UNIT WALL MOUNTED TYPE ASTG18KMCA ASTG22KMCA ASTG24KMCA DTR_AS082E_02 2013 09 13 ...
Page 221: ...2 OUTDOOR UNIT SINGLE TYPE AOTG18KMCA AOTG22KMCA AOTG24KMCA DTR_AO144E_02 2013 09 13 ...
Page 236: ... 02 14 OUTDOOR UNIT AOTG18 24KMCA OUTDOOR UNIT AOTG18 24KMCA SOUND LEVEL CHECK POINT 88888 ...
Page 264: ...1208G4097 ...