En-3
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
1 Intake
grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing may have an effect on the proper
function or performance of the product.
2 MANUAL AUTO button
Use when the remote controller is lost or there is a malfunction.
Status
Action
Mode or operation
In operation
Press more than 3 seconds.
Stop
Stopping
Press more than 3 seconds and
less than 10 seconds.
AUTO
Press more than 10 seconds.
(Only for servicing.*)
Forced cooling
After cleaning
Press less than 3 seconds.
Filter indicator reset
*:To stop forced cooling, press this button or START/STOP button on
the remote controller.
3 Front
panel
See page 8
4 Human
Sensor
Used for Energy Saving Program. Controls temperature setting by
detecting people in the room.
5 Vertical
air
fl
ow direction louver
Each time you press Vertical SET button on the remote controller, the
angle of the vertical air
fl
ow direction louver moves as follows:
1
2
3
4
5
6 7 8
COOL or DRY mode
HEAT mode
1
2
3
7
6
5
*
4
8
*
*: Default setting in each mode.
• Do not adjust by hand.
• At the beginning of AUTO or HEAT mode, they may stay on position
1 for a while for adjustment.
• If the angle is set to position 5-8 for more than 30 minutes in COOL
or DRY mode, the louver will automatically return to position 4.
• Keeping the position 5-8 during COOL or DRY mode may cause
condensation to form, and the drops may damage your property.
6 Power
diffuser
In conjunction with movement of the vertical air
fl
ow direction louver,
the angle of the power diffuser moves as follows:
Vertical air
fl
ow
direction louver
Power diffuser
3
7
6
5
4
2
1
8
• In SWING operation, power diffuser does not move.
7 Horizontal
air
fl
ow direction louver
Each time you press the Horizontal SET button on the remote controller,
the air
fl
ow direction range of the horizontal air
fl
ow direction louver will
change as follows:
1
2
3
4
5
Horizontal air
fl
ow direction louver
5
4
1
3
*
2
*: Default setting.
8 Drain
hose
9 Remote controller signal receiver
CAUTION
For appropriate signal transmission between remote controller and
indoor unit, keep the signal receiver away from the following items:
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous
fl
uorescent lights, such as in-
verter type ones, the signal may not be transmitted properly. In
such a case, consult the store of purchase.
1
14
13
11
12
8
3
4
2
7
5
6
10
9
10 ECONOMY indicator (green)
Lights in ECONOMY operation and in 10 °C HEAT operation.
11 TIMER indicator (orange)
Lights in TIMER operation, and blinks slowly when the timer setting
error is detected.
For details, refer to “Auto-restart function” on page 9.
12 OPERATION indicator (green)
Lights in normal operation, and blinks slowly in Automatic defrosting
operation.
Blinks during Demand Response operation. For details, refer to page
8.
See page 10
13 Air
fi
lter
See page 11
14 Air cleaning
fi
lters
Purify or deodorize the air, and provide fresh air
fl
ow.
Indoor Unit Overview and Operations
9320455002_OM_EN.indd 3
9320455002_OM_EN.indd 3
7/23/2013 10:34:40 AM
7/23/2013 10:34:40 AM
Summary of Contents for AOTG36LATT
Page 4: ...2008 11 20 3 31 12 330 900 1290 9 21 OUTDOOR UNIT unit mm 650 400 370 air flow ...
Page 30: ...1204G4067 ...
Page 34: ...Unit mm 2012 05 29 3 AOTG12LVCC OUTDOOR UNIT AOTG09LVCC 540 290 790 540 540 660 290 450 ...
Page 60: ...1205G4083 ...
Page 85: ...1307G4239 ...
Page 113: ......
Page 114: ...1 DESCRIPTION OF EACH CONTROL OPERATION WALL MOUNTED type INVERTER ...
Page 135: ......
Page 136: ...2 TROUBLE SHOOTING WALL MOUNTED type INVERTER ...
Page 169: ......
Page 170: ...3 APPENDING DATA WALL MOUNTED type INVERTER ...
Page 176: ...4 INSTALLATION WORK WALL MOUNTED type INVERTER ...
Page 181: ......
Page 187: ......
Page 188: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan September 2013 Printed in Japan ...
Page 190: ...1 INDOOR UNIT WALL MOUNTED TYPE ASTG18KMCA ASTG22KMCA ASTG24KMCA DTR_AS082E_02 2013 09 13 ...
Page 221: ...2 OUTDOOR UNIT SINGLE TYPE AOTG18KMCA AOTG22KMCA AOTG24KMCA DTR_AO144E_02 2013 09 13 ...
Page 236: ... 02 14 OUTDOOR UNIT AOTG18 24KMCA OUTDOOR UNIT AOTG18 24KMCA SOUND LEVEL CHECK POINT 88888 ...
Page 264: ...1208G4097 ...