AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
General Informations on Operation
Automatic defrosting operation
When outdoor temperature is very low with high humidity, frost
may form on the outdoor unit during the heating operation, and
it could reduce the operating performance of the product.
For frost protection, a microcomputer-controlled automatic
defrost function is equipped in this air conditioner.
If frost forms, the air conditioner will temporarily stop, and
defrost circuit will operate brie
fl
y (maximum of 15 minutes.)
OPERATION indicator on the indoor unit blinks during this
operation.
If frost forms on the outdoor unit after the heating operation, the
outdoor unit will stop automatically after it operates for a few
minutes. Then the automatic defrosting operation starts.
Auto-restart function
In event of power interruption such as a blackout, the air
conditioner stops once. But it restarts automatically and
performs previous operation when the power supply is resumed.
If any power interruption occurs after the timer is set, counting
down of the timer will be reset.
After the power supply is resumed, the TIMER indicator on the
indoor unit blinks to notify you that there has been a timer fault.
In such a case, reset the timer for your opportune time.
Malfunctions caused by other electrical devices:
Use of other electrical appliances such as an electric shaver or
nearby use of a wireless radio transmitter may cause the malfunction
of the air conditioner.
If you encounter such a malfunction, turn off the circuit breaker once.
Then turn it on again, and resume operation by using the remote
controller.
Heating performance
This air conditioner operates on the heat-pump principle,
absorbing heat from air outdoors and transferring that heat
to the indoor unit. As a result, the operating performance is
reduced as outdoor air temperature drops. If you feel that the
heating performance is insuf
fi
cient, we recommend you to use
this air conditioner in conjunction with other kinds of heating
appliance.
Temperature and Humidity Range
Permissible ranges of temperature and humidity are as follows:
COOL/DRY
Indoor temperature
About 18 °C to 32 °C
Indoor humidity
Below approximately 80%.
If the air conditioner is used continuously for many
hours, water may condense on the surface and drip.
HEAT
Indoor temperature
About 16 °C to 30 °C
If the unit is used under higher temperature conditions than those noted here, the automatic protection circuit may operate, interrupting the operation.
If the unit is used under lower temperature conditions than those noted here, the heat exchanger may freeze, causing water leakage or other mal-
function.
●
Do not use the air conditioner for any purpose other than room cooling/dry, room heating or fan.
9320455002_OM_EN.indd 9
9320455002_OM_EN.indd 9
7/23/2013 10:34:48 AM
7/23/2013 10:34:48 AM
Summary of Contents for AOTG36LATT
Page 4: ...2008 11 20 3 31 12 330 900 1290 9 21 OUTDOOR UNIT unit mm 650 400 370 air flow ...
Page 30: ...1204G4067 ...
Page 34: ...Unit mm 2012 05 29 3 AOTG12LVCC OUTDOOR UNIT AOTG09LVCC 540 290 790 540 540 660 290 450 ...
Page 60: ...1205G4083 ...
Page 85: ...1307G4239 ...
Page 113: ......
Page 114: ...1 DESCRIPTION OF EACH CONTROL OPERATION WALL MOUNTED type INVERTER ...
Page 135: ......
Page 136: ...2 TROUBLE SHOOTING WALL MOUNTED type INVERTER ...
Page 169: ......
Page 170: ...3 APPENDING DATA WALL MOUNTED type INVERTER ...
Page 176: ...4 INSTALLATION WORK WALL MOUNTED type INVERTER ...
Page 181: ......
Page 187: ......
Page 188: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan September 2013 Printed in Japan ...
Page 190: ...1 INDOOR UNIT WALL MOUNTED TYPE ASTG18KMCA ASTG22KMCA ASTG24KMCA DTR_AS082E_02 2013 09 13 ...
Page 221: ...2 OUTDOOR UNIT SINGLE TYPE AOTG18KMCA AOTG22KMCA AOTG24KMCA DTR_AO144E_02 2013 09 13 ...
Page 236: ... 02 14 OUTDOOR UNIT AOTG18 24KMCA OUTDOOR UNIT AOTG18 24KMCA SOUND LEVEL CHECK POINT 88888 ...
Page 264: ...1208G4097 ...