Wall mounted type (For KMTB and KMCC)
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
ASHG07KMTB
ASHG07KMCC
ASHG09KMTB
ASHG09KMCC
ASHG12KMTB
ASHG12KMCC
ASHG14KMTB
ASHG14KMCC
Heating
POWERFUL
1,210
1,250
1,270
1,360
HIGH
1,140
1,180
1,200
1,290
MED+
1,040
1,040
1,100
1,160
MED
950
970
1,030
1,100
LOW
800
810
880
910
QUIET
630
630
630
670
Cool air
prevention
550
550
550
580
S-LOW
400
400
400
470
Cooling/Fan
POWERFUL
1,120
1,180
1,180
1,320
HIGH
1,050
1,110
1,110
1,250
MED
900
920
920
1,020
LOW
760
760
760
810
QUIET
550
550
550
580
Soft quiet
470*
1
470*
1
470*
1
510*
1
S-LOW
400*
2
400*
2
400*
2
470*
2
Dry
X zone: 550
J zone: 550
X zone: 550
J zone: 550
X zone: 550
J zone: 550
X zone: 580
J zone: 580
*1: Fan mode only
*2: Cooling mode only
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
Cooling operation
Switch the airflow AUTO, and indoor fan motor will run according to room temperature, as below.
On the other hand, if switched in HIGH—QUIET, indoor motor will run at a constant airflow of COOL
operation modes QUIET, LOW, MED, HIGH as shown in “Fan speed” above.
Airflow change over (Cooling: Auto)
When room
temperature rises
When room
temperature drops
Tr - Ts ≥ 1.5
°C
MED mode
LOW mode
LOW mode
1.5
°C
> Tr - Ts ≥ 0.5
°C
0.5
°C > Tr - Ts
Tr - Ts ≥ 2.5
°C
2.5
°C
> Tr - Ts ≥ 1.5
°C
1.5
°C > Tr - Ts
Dry operation
During dry operation, fan speed setting can not be changed as shown in “Fan speed” above.
3-1. Indoor fan control
- (04-43) -
3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AGHG09KVCA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 03 15 SR_CH01_MU001EG_04 ...
Page 40: ...2 6 Outdoor unit 01 34 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 41: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 15 SR_CH02_MU001EG_05 ...
Page 44: ......
Page 161: ...3 TROUBLESHOOTING 2022 04 13 SR_CH03_MU001EG_04 ...
Page 164: ......
Page 259: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU001EG_06 ...
Page 262: ......
Page 351: ...5 FILED WORKING 2022 04 13 SR_CH05_MU001EG_05 ...