1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
•
Cooling/Dry mode
F zone
18°C
E zone
12°C
D zone
7°C
C zone
B zone
A zone
-3°C
-8°C
G zone
22°C
H zone
38°C
Unit: rps
Model name
Outdoor temperature zone
Limitation of compressor
rotation number
AOHG14KBTA2
A zone
40
B zone
25
C zone
25
D zone
19
E zone
19
F zone
19
G zone
18
H zone
23
AOHG18KBTA2
A zone
30
B zone
30
C zone
23
D zone
18
E zone
13
F zone
11
G zone
11
H zone
25