Wall mounted type (For KETE)
•
Rotation number range of compressor
Unit: rps
Connected model name
Minimum rotation number
Maximum rotation number
AOHG14KBTA2
12
89
AOHG18KBTA2
8
94
•
Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
– Model: AOHG14KBTA2
Model name
Outdoor
temperature
zone
Indoor unit fan mode
HIGH
MED
LOW
QUIET
ASHG07KETE
ASHG07KETE-B
A zone
89
50
38
18
B zone
89
50
38
18
C zone
50
38
34
18
D zone
38
34
30
18
E zone
38
34
30
18
F zone
38
34
30
18
ASHG09KETE
ASHG09KETE-B
ASHG12KETE
ASHG12KETE-B
ASHG14KETE
ASHG14KETE-B
A zone
89
50
38
14
B zone
89
50
38
14
C zone
50
38
34
14
D zone
38
34
30
14
E zone
38
34
30
14
F zone
38
34
30
14
1-1. Cooling operation
- (04-11) -
1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AGHG09KVCA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 03 15 SR_CH01_MU001EG_04 ...
Page 40: ...2 6 Outdoor unit 01 34 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 41: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 15 SR_CH02_MU001EG_05 ...
Page 44: ......
Page 161: ...3 TROUBLESHOOTING 2022 04 13 SR_CH03_MU001EG_04 ...
Page 164: ......
Page 259: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU001EG_06 ...
Page 262: ......
Page 351: ...5 FILED WORKING 2022 04 13 SR_CH05_MU001EG_05 ...