Wall mounted type (For KGTE)
•
Rotation number range of compressor
Unit: rps
– Model: AOHG14KBTA2
Model name
Outdoor temperature zone
Operating rotation number
ASHG07KGTE
X zone
18
J zone
18
Y zone
0
ASHG09KGTE
ASHG12KGTE
ASHG14KGTE
X zone
14
J zone
14
Y zone
0
– Model: AOHG18KBTA2
Model name
Outdoor temperature zone
Operating rotation number
ASHG07KGTE
X zone
14
J zone
14
Y zone
0
ASHG09KGTE
ASHG12KGTE
ASHG14KGTE
X zone
10
J zone
10
Y zone
0
•
Compressor control based on room temperature
Ts+0.5°C
Ts -1.5
°C
Ts-0.5
°C
Ts+1.5
°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature
1-3. Dry operation