Check point 3. Check the wired remote controller and controller PCB
[Compact cassette and floor types]
Check voltage at CN14 (terminal 1—3, terminal 1—2) of main PCB.
(Power supply to remote controller)
•
If it is DC 12 V, the remote controller is failure. (The controller PCB is normal)
-> Replace the remote controller.
•
If it is DC 0 V, the controller PCB is failure. (Check the remote controller once
again)
-> Replace the controller PCB.
[Wall mount type for KGTB, KGTE, KMCE, KETA, KETE]
Check voltage at CN300 (terminal 1—2) of main PCB or communication PCB.
(Power supply to remote controller)
•
If it is DC 12 V, the remote controller is failure. (The controller PCB is normal)
-> Replace the remote controller.
•
If it is DC 0 V, the controller PCB is failure. (Check the remote controller once
again)
-> Replace the controller PCB.
[Wall mount type for KMTB, KMCC]
Check voltage at CNC01 (terminal 1—3) of main PCB or communication PCB.
(Power supply to remote controller)
•
If it is DC 13 V, the remote controller is failure. (The controller PCB is normal)
-> Replace the remote controller.
•
If it is DC 0 V, the controller PCB is failure. (Check the remote controller once
again)
-> Replace the controller PCB.
[Mini duct and Slim duct types]
Check voltage at CN300 (terminal 1—3, terminal 1—2) of main PCB.
(Power supply to remote controller)
•
If it is DC 12 V, the remote controller is failure. (The controller PCB is normal)
-> Replace the remote controller.
•
If it is DC 0 V, the controller PCB is failure. (Check the remote controller once
again)
-> Replace the controller PCB.
↓
Check point 4. Replace the main PCB
If check point 1 to 3 do not improve the symptom, replace the main PCB.
↓
End
3-3. No operation (Power is on)
- (03-61) -
3. Troubleshooting without error code
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for AGHG09KVCA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 03 15 SR_CH01_MU001EG_04 ...
Page 40: ...2 6 Outdoor unit 01 34 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 41: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 15 SR_CH02_MU001EG_05 ...
Page 44: ......
Page 161: ...3 TROUBLESHOOTING 2022 04 13 SR_CH03_MU001EG_04 ...
Page 164: ......
Page 259: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU001EG_06 ...
Page 262: ......
Page 351: ...5 FILED WORKING 2022 04 13 SR_CH05_MU001EG_05 ...