7-14. Human sensor for energy saving (For KGTB, KGTE,
KMTB, and KMCC series Wall mounted type)
If no one enters the room for approximately 20 minutes, the set temperature is automatically con-
trolled. (When someone comes back into the room, the human sensor detect this, and automatically
revert to the original settings.)
Operation mode
Operation details
(If there is no one in the room for a while)
Cool/Dry
The setting temperature is increased by maximum 2°C.
(Maximum setting temperature: 30°C)
Heat
The setting temperature is decreased by maximum 4°C.
(Minimum setting temperature: 16°C)
Auto
Energy saving function is performed automatically for the selected mode
(cool/heat/dry).
• Application range:
Vertical angle 90
°
Side view
Horizontal angle 100
°
Top view
90
°
6 m
50
°
50
°
6 m
Energy saving function may not work when the room temperature is very different from the tem-
perature defined in the temperature setting, such as when immediately after starting the operation.
• Details about detection with the human sensor:
The human sensor detects whether there are people in the room by looking for movement by peo-
ple in the room.
7-14. Human sensor for energy saving (For KGTB, KGTE, KMTB, and KMCC series
Wall mounted type)
- (04-82) -
7. Various control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AGHG09KVCA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 03 15 SR_CH01_MU001EG_04 ...
Page 40: ...2 6 Outdoor unit 01 34 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 41: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 15 SR_CH02_MU001EG_05 ...
Page 44: ......
Page 161: ...3 TROUBLESHOOTING 2022 04 13 SR_CH03_MU001EG_04 ...
Page 164: ......
Page 259: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU001EG_06 ...
Page 262: ......
Page 351: ...5 FILED WORKING 2022 04 13 SR_CH05_MU001EG_05 ...