45
5. Inspection
FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
5.
Inspection
5-1. Measuring Instruments and Jigs Used for Inspection
Measuring instrument
Remarks
TV monitor
NTSC TV monitor, minimum resolution 600 lines
Power supply
AC adapter (eg AC-5VH), stabilized power supply
Pattern box
PTB450 or equivalent
Waveform monitor
LEADER: 5870 or equivalent
Digital voltmeter
For general use
Luminance meter
LS-110 (Minolta) or equivalent
Color thermometer
Color Meter IIIF (Minolta) or equivalent
Ammeter
For general use (able to measure up to 1mA)
NP60 battery jig
Common with adjustment jig: ZJ00496-100
Power cable jig
Common with adjustment jig: ZJ00213-100
Grey chart
Common with adjustment jig: ZJ00254-100
LB140 filter
Common with adjustment jig: ZJ00006-100
High-resolution chart
Common with FinePixS1Pro, FinePix4700Z: ZJ00398-100
5-2. Connection of Measuring Instruments for Inspection
* As the FinePix F601 has no video output, the FinePix4800Z is used to illustrate connection of the measuring
instruments.
Any other camera with a video output function may also be used provided that it is not malfunctioning.
5-3. Inspection and Settings at Shipment
<Step 1>
FinePix4800Z
VIDEO OUT
Power supply
(AC-5VH, stabilized power supply)
Waveform
monitor
TV monitor
Vector
scope
Amme-
ter
Item
Visual check
Mode
------
Preparations for adjustment
and measurement
Visual check of camera.
Adjustment and measurement
method
• No significant dents in body.
• Click sound of all switches, and
operation of sliders, normal.
• No significant foreign matter, or
cloudiness, in viewfinder.
• Flash mechanism opens and
closes smoothly.
Measuring
instrument
------
Measurement
point
------