4. Adjustment
30
FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
<STEP5>
Select [Hardware] on the [Customize] setup screen (Fig.I-
(1)).
Setup as follows on the [Hardware] menu (Fig.I-(2)).
Item
Setup details
Debug Mode
Select [Ignore Focus].
<STEP6>
When the settings have been entered in the [EVR], [Oth-
er], and [Hardware] menus noted above, click on [Apply]
on the [Customize Dialog] screen (Fig.I-(3)) to terminate.
Further setup is unnecessary once the settings have
been applied.
(note) Setting [Don’t show OK/NG] to OFF will allow [OK] to
be displayed on the computer screen if the adjust-
ment is successful, and [NG] to be displayed if it is
not (either setting can be used).
Cautions for Adjustment
(note 1) The end setting returns the camera to the
[Product Mode] from the [Jig Mode].
Always ensure that the camera is returned
to the [Product Mode] before use after us-
ing the computer adjustment software.
Unless this termination setting is selected,
[Mass Storage] will not be recognized
when the camera and computer are con-
nected, and communication with the com-
puter will be impossible.
(note 2) FinePix_F601 may be used with other dig-
ital cameras, however data read and write
is not possible.
It is possible to read data from other mod-
els, however this should not be attempted
under any circumstances.
See Table 1 at right.
(1)
(2)
(3)
<Fig.I> Hardware Dialog Box Screen
Menu
Command
Description
Operation
Start
Program start
Stop
Program stop
Temporary stop
Temporary program stop
Step 0
Do not use.
Terminate
Terminate program.
Program
Reload
Reload program (*.ff).
Select
Select program (*.ff).
Edit
Edit program (*.ff).
Data
ad[ ]
Do not use.
rd [ ]
Do not use.
SW
Do not use.
f s w
Do not use.
EVR
Do not use (Note 2).
Mode
Record file
Do not use.
NGSTOP
Temporarily stops program
when adjustment is unsuc-
cessful.
STEP
Do not use.
LINE
Do not use.
AUTO
Do not use.
Setting
OK/NG clear
Do not use.
Mode set
Sets mode.
Automatic
Runs ‘Auto Adjust’ inside the
adjustment
user program.
Help
Help
Basic software help
FF help
User program help
FOCAS
Not used with this adjust-
ment software.
Version
Version information for
basic software.
<Table 1> FFWJ.exe Commands
* Do not change the content of the program FX_F601_UED.ff
under any circumstances. Any changes will prevent the
software running.
Apply
Fx_F601_UED.ff