4. Adjustment
FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
4-9. Adjustment Software Initial Setup
*
As the initial setup has already been written to the
[FFW217.ini] file, all that is required is to follow the pro-
cedure below.
Note that changing the file name may prevent the soft-
ware running.
*
As steps 3, 4, 5, and 6 of initial setup are incorporated in
the [FFW217.ini] file, confirmation is the only action re-
quired.
*
Do not change the content of the program FX_F601_UED.ff
under any circumstances. Any changes will prevent the
software running.
<STEP1>
Double-click on the adjustment software executable file
[FFW217.exe] (Fig.D-(2)) to display the [FFW217 Start-
up Screen] (Fig.E).
<STEP2>
Select [Mode Settings] (Fig.F-(2)) from the [Setting] menu
(Fig.F-(1)) on the [MENU Screen].
<STEP3>
Select the [EVR & Communications] menu on the [Cus-
tomize] dialog screen (Fig.G-(1)).
Setup as follows on the [EVR] menu (Fig.G-(2)).
Item
Setup details
etc (-V2)
Use (=check)
LANC page
Use (=check)
<STEP4>
Select the [Etc] menu on the [Customize] dialog screen
(Fig.H-(1)).
Setup as follows on the [Etc] menu (Fig.H-(2)).
Item
Setup details
Auto-measure
0
Change mode
Do not check (=not used)
Use Japanese font
Do not check (=not used)
<Fig.E> FFW217 Start-up Screen
<Fig.F> Mode Setting Display Select Screen
(1)
(2)
Fx_F601_UED.ff
<Fig.H> Etc Customize Dialog Box Screen
Fx_F601_UED.ff
<Fig.G> EVR Dialog Box Screen
(2)
(1)
Fx_F601_UED.ff
(1)
(2)
Fx_F601_UED.ff
Apply
Apply