4. Adjustment
FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
4-5. Jig Connections
note 1:
Always measure input voltage in the vicinity of the DC IN terminal when making adjustments.
note 2:
The AC adapter may be used during all adjustments using the DC jack except for DC jack voltage adjustment.
DC IN terminal
V o l t m e t e r
(note 1)
Power cable jig (note 2)
* Connection depends on ad-
justment details.
Personal computer
USB cable
FinePix F601
Stabilized power supply
DC5V
Stabilized power supply
DC5V
NP60 battery jig
* Connection depends on
adjustment details.
OS:Windows98
4-6. Setup for Adjustments
(1) Setup for Camera Adjustment (Fig.A)
<< All white pattern >>
Adjust the distance between the reference surface(*1)
and the pattern box to a maximum of 50mm.
Place the filter (LB140) firmly against the reference
surface.
1) Color temperature: 6100±50K (with LB140 filter)
Measurement position: Middle of pattern box
Measuring instrument: Minolta Color Meter IIIF or equiv-
alent
* Measuring color temperature
Place the filter (LB140) firmly against the pattern box.
Adjust the color temperature of the pattern box to
6100±50K with the filter (LB140) against the color
thermometer.
2) Luminance: 160±5cd/m
2
(with LB140 filter)
Measurement position: Middle of pattern box
Measuring instrument: Minolta luminance meter LS-
110 or equivalent
* Measuring luminance
Place the filter (LB140) firmly against the pattern box.
Adjust the luminance of the pattern box to 160±5cd/m
2
with the filter (LB140) against the luminance meter.
Camera
Filter (LB140)
Pattern box
Setup for Camera Adjustment
Maximum
30mm
Centerline
Maximum 50mm
Maximum 80mm
*1 Use front of LENS CONST as camera reference sur-
face.