Note:
Please consult Installation Manual for detailed instructions.
Unloading Instructions:
Upon delivery, inspect Fuji Clean tank, both outside and inside for possible damage incurred during
transport. If you find damage, or have a question, please contact your distributor immediately.
Step 1: Prepare excavation to be at least 1 to 2 feet larger than the Fuji Clean tank dimensions. Note:
Riser height should not exceed 24”.
Step 2: Prepare 4”- 6” bed of stone (1/8”) sand, or poured concrete level to within 1/8”.
Step 3: Use 4-point lifting lugs. Carefully lower and set tank. Level to within 1/8-inch per 2-ft.
Step 4: If any part of the tank is below the estimated seasonal high water table, adequate tank uplift
restraint measures should be taken. Please refer to Installation Manual for recommended options.
Step 5: Re-check that tank is level to 1/8-inch per 2-ft., (fore and aft as well as side to side) and then fill
tank with fresh water to the low water line (marked inside tank). Start 24-hour water tightness test. (Please
contact your distributor or Fuji Clean USA if water level has dropped after 24 hours).
Step 6: Backfill about ¾ way up tank in layered, compacted 6” lifts using peastone or equivalent material
that form-fits into tank corrugations. Install inlet/outlet lines using 5x4 reducing bushing if necessary.
Step 7: Using supplied adaptors and fittings, attach air pipe fitting to tank and connect to ¾” or 1” conduit
in prepared trench (min. 6” deep) to location of air blower. For CE14, 21, CEN10 and 14, locate blower within
33’ for ¾” or 1” air line or 100’ for 1” air line. For CE30 and CEN21 use 1” air line. Connect with no more than
5 elbows on each models.
Step 8: Locating and Installing Blower/ Control Panel.
Air Blower shall be:
in as close proximity to control panel as possible
on a solid (e.g. concrete) pad to minimize vibrations
in a location above water level
away from grease exhaust fans.
away from bedroom windows and other locations where operational sounds (although minimal)
may be a nuisance
In a location that allows unencumbered access for inspection and maintenance activity
with proper electrical grounding
with wiring and electrical connections made by a licensed electrician.
with no objects on top of electrical cord.
in a well-ventilated space out of direct sunlight and protected from elements such as direct rain
or snowfall.
No-traffic Area Installation Procedure Checklist
42