13
Step 8: Locating and Installing Blower/Control Panel.
Air Blower shall be:
in as close proximity to control panel as possible
on a solid (e.g. concrete) pad to minimize vibrations
in a location above water level
away from grease exhaust fans
away from bedroom windows and other locations
where operational sounds (although minimal) may be
a nuisance
in a location that allows unencumbered access for
inspection and maintenance activity
with proper electrical grounding
with wiring and electrical connections made by a
licensed electrician
with no objects on top of electrical cord
in a well-ventilated space out of direct sunlight and
protected from elements
Alarm Panel shall be:
in a well ventilated area as dry and protected from
elements as much as possible
in as close of proximity to FujiMAC air blower as
possible
wired by qualified electrician
in a location that allows unencumbered access for
inspection and maintenance activity
Be sure to vent blower protection cover to
allow free air draw even in deep snow pack.
Note: For Fuji Clean models CE30 and CEN21 (which both
require two blowers), the 1/8” (ID) Vinyl Micro-Tubing for
Air Pressure Sensing Alarm is replaced with current sensing
switches, supplied with the “M” panel.
Please provide
service contact
information on
the control panel.
¾”
¾”
1”