19
Step 7: Using supplied adaptors
and fittings, attach air pipe fitting
to tank and connect to ¾” or 1”
conduit in prepared trench (min. 6”
deep) to location of air blower.
Please note: ¾” or 1” flexible
irrigation line, 100 PSI Max, (or
equivalent) may also be used for
the air line.
For connection air line to tank, use
sealant meeting ASTM C990-96
standard to prevent septic gas
transmission into control panel.
(Note: Adaptors to tank are not necessary for air line to tank
connection for Fuji Clean models, CE21 and larger and CEN14
and larger. Use 3/4” conduit). Adaptors to tank are necessary
for air line to tank connection for CE14 and CEN10.
LOCATE BLOWER WITHIN 33-FT OR 100-FT OF TREATMENT
TANK (FOLLOW CONDUIT ON TABLE BELOW) AND WITH NO
MORE THAN FIVE (5) ELBOWS. Refer to elbow counting page 13.
If site conditions prevent this, please contact your distributor
or Fuji Clean USA for technical assistance.
3/4” PVC air line can insert directly
into commercial tank models, CE21
and larger and CEN14 and larger.
CE14/CEN10
FujiMAC 150RII
CE21/CEN14
FujiMAC 200RII
CE30/CEN21
FujiMAC 150RII (2)
Blower Outlet Pipe
3/4”
Air Intake at Tank
φ13
※
φ20
※
φ20
※
Blower to Tank Distance /
Airline Conduit Dia.
<33 Feet /
3/4”
<100 Feet/
1”
< 33 Feet
3/4”
<100 Feet
1”
<33 Feet
1”
<100 Feet
1”
Step 7 continued: Set riser on the tank.
Step 8: Locating and Installing Blower/Control Panel. Please refer the details page 14.
Step 9: Float switch electrical cord connect through a male adaptor (caulked watertight to
prevent septic gas leakage) or watertight fitting. An interior connection to direct burial cable is
also an acceptable option.
※
Japanese pipe dia.