INZ-TN7ZSS-E
- 103 -
List for Combinations of Measureable Components, Units and Measurement ranges
Component Measuring
range
CO
0 ~ 2, 2.5, 4, 5, 10, 15, 20, 25, 50 vol%
CO (For use in high temp.)
0 ~ 10, 15, 20, 25, 50 vol%
HCl
0 ~ 10, 15, 20, 25, 50, 100, 200, 250, 400, 500, 1000, 2000, 5000 ppm or mg/m
3
CO
2
0 ~ 2, 2.5, 4,5, 10, 15, 20, 25, 50 vol%
CO
2
(For use in high temp.)
0 ~ 10, 15, 20, 25, 50 vol%
O
2
0 ~ 4, 5, 10, 15, 20, 25, 50, 100 vol%
O
2
(For use in high temp.)
0 ~ 4, 5, 10, 15, 20, 25, 50 vol%
O
2
(For air purge)
0 ~ 25, 50, 100 vol%
CH
4
0 ~ 100, 200, 250, 400, 500, 1000, 2000, 5000 ppm or mg/m
3
NH
3
0 ~ 15, 20, 25, 50, 100, 200, 250, 400, 500, 1000, 2000, 5000 ppm or mg/m
3
CO+CO
2
1st comp.: CO
0 ~ 2.5, 4, 5, 10, 15, 20, 25, 50 vol%
2nd comp.: CO
2
0 ~ 2.5, 4, 5, 10, 15, 20, 25, 50 vol%
CO+CO
2
(For use in high temp.)
1st comp.: CO
0 ~ 10, 15, 20, 25, 50 vol%
2nd comp.: CO
2
0 ~ 10, 15, 20, 25, 50 vol%
CO+O
2
(Air purge)
1st comp.: CO
0 ~ 200, 250, 400, 1000, 2000, 5000, 6000 ppm, 2vol%
2nd comp.: O
2
0 ~ 25, 50, 100 vol%
CO+O
2
(High temperature)
1st comp.: CO
0 ~ 200, 250, 400, 1000, 2000, 5000, 6000 ppm, 2vol%
2st comp.: O
2
0 ~ 5, 10, 15, 20, 25, 50 vol%
CO+O
2
1st comp.: CO
0 ~ 4, 5, 10, 15, 20, 25, 50 vol%
2st comp.: O
2
0 ~ 10, 15, 20, 25, 50, 100 vol%
Scope of delivery
•
Receiver
unit
•
Transmitter
unit
•
Control
unit
•
Cable between receiver unit and transmitter unit (specified length)
•
Cable between receiver unit and control unit (specified length)
•
Standard accessory set, instruction manual
Optional items
•
Spare parts for one year (ZBN1SS12)
•
Calibration gas cell (*1) (*2)
•
Cable between receiver unit and transmitter unit (*1)
•
Cable between receiver unit and control unit (*1)
•
Standard gas (ZBM), pressure regulator (ZBD)
•
Recorder (when necessary, Fuji's product type PHR, etc.)
•
Others
*1: Although there is no need to arrange the item for each equipment, there must be at least 1 item for
each installation location.
*2: The length of calibration gas cell might be changed by measuring range.
Standard accessories
Name Quantity Specification
Bolt
8 (16)
M16×55 (70) SUS (*)
Nut
8 (16)
M16 SUS (*)
Spring washer
8 (16)
M16 SUS (*)
Flat washer
8 (16)
M16 SUS (*)
Companion flange packing or
flange packing specified for use in
high temperature
2
According to flange rating
Bolt for angle fine adjustments
6
Hexagonal socket bolt M8 × 70
Power supply fuse
2
(* When B is selected for the 9th digit of the code symbols, quantity becomes 16. In other cases, quantity is
8. When B, C or D is selected for the 9th digit of the code symbols, the length of the bolt becomes 70mm.
In other cases, it is 55mm. (inch bolt is not supplied.))