![Fuji Electric Time Delta-C FSV-2 Instruction Manual Download Page 139](http://html1.mh-extra.com/html/fuji-electric/time-delta-c-fsv-2/time-delta-c-fsv-2_instruction-manual_2341899139.webp)
-132-
<
Parameter specification table Measurement mode: 2-pipe>
Setting item
Initial value
Setting value
Setting range
ID No
0000
ID No. is invalid when 0000 is selected.
Language
Japanese
English, Japanese, German, French,
Spanish
Measurement mode
2 pipes
1 path, 2 path, 2 pipes
Calculation output
Average
Average, Addition, Sub (CH1-CH2),
Sub (CH2-CH1)
Action mode
Normal
Normal, High speed
System unit
Metric
Metric or Inch
Setting item
Initial value
Path 1 (CH1)
Path 2 (CH2)
Setting range
Flow unit
㎥
/h
L/s
,
L/min
,
L/h
,
L/d
,
kL/d
,
ML/d
,
m
3
/s
,
m
3
/min
,
m
3
/h
,
m
3
/d
,
km
3
/d
,
Mm
3
/d
,
BBL/s
,
BBL/min
,
BBL/h
,
BBL/d
,
kBBL/d
,
MBBL/d
Unit
Total unit
㎥
mL
,
L
,
m
3
,
km
3
,
Mm
3
,
mBBL
,
BBL
,
kBBL
Outer diameter
60.00mm
6.00 to 6200.00mm
Pipe material
PVC
Carbon steel, Stainless, PVC, Copper,
Cast
iron, Aluminum, FRP, Ductile iron, PEEK,
PVDF, Acrylic and PP
Pipe sound velocity
(Sound velocity: [m/s,
ft/s])
Wall thickness
4.00mm
4.00mm
Lining material
No lining
No lining, Tar epoxy, Mortar, Rubber,
Teflon,
Pyrex glass, PVC
Lining S.V. (Sound velocity: [m/s,
ft/s])
Lining thickness
―
0.01 to 100.00mm
Kind of fluid
Water
Water, seawater, dist. water, ammonia,
alcohol,
benzene, bromide, ethanol, glycol,
kerosene,
milk, methanol, toluol, lube oil, fuel oil,
petrol
and refrigerant R410
Fluid S.V. (Sound velocity: [m/s,
ft/s])
Viscosity
1.0038×10
-6
㎡
/s
0.001 to 999.999×10
-6
m
2
/s
Sensor mounting method
V method
V method, Z method
Measuring conditions
Pr
ocess setting
Sensor type
FSSA
FSSA/FSSG,FLS_12/FLS_22,FSSC,FSG
_32,
FSG_31/FSG_41,FSSE/FSG_50FSSF/FS
G_51, FSD12,FSSD/FSD22,FSSH/FSD32
Setting item
Initial value
Path 1
(CH1)
Path 2
(CH2)
Calculat
ed value
(CH3)
Setting range
Damping 5.0
sec
―
0.0 to 100.0sec
Low flow cut
0.15
㎥
/h
―
0 to 5m/s in terms of flow velocity
Analog output 1 source
channel
CH1: Flow rate
CH1: Flow rate, CH2: Flow rate, CH3:
Flow rate (Note2)
Analog output 2 source
channel
CH2: Flow rate
CH1: Flow rate, CH2: Flow rate, CH3:
Flow rate (Note2)
Kind Flow
rate
Flow
rate
Velocity, Flow rate
Range type
Single
Single, Auto 2, Bi-dir, Bi-dir Auto 2
Full scale 1
15.000
㎥
/h
0, ±0.3 to ±32m/s in terms of flow velocity
Full scale 2
0.000
㎥
/h
0, ±0.3 to ±32m/s in terms of flow velocity
Hysteresis
10.00 %
0.00 to 20.00%
Burnout (current)
Hold
Not used, Hold, Lower, Upper and Zero
Burnout timer
10 sec
10 to 900sec
Output limit low
-20 %
-20 to 0%
Analog output
Output limit high
120 %
100 to 120%
Total mode
Stop
Start, Stop, Reset
Total rate
0
㎥
0.000000
to
99999999
Total preset
0
㎥
0.000000
to
99999999
Pulse width
50msec
5msec
,
10msec
,
50msec
,
100msec
,
200msec
,
500msec
,
1000msec
Burnout (total)
Hold
Not used, Hold
Output condition
s
To
ta
l output
Burnout timer
10 sec
10 to 900sec