![Fuji Electric Time Delta-C FSV-2 Instruction Manual Download Page 135](http://html1.mh-extra.com/html/fuji-electric/time-delta-c-fsv-2/time-delta-c-fsv-2_instruction-manual_2341899135.webp)
-128-
7.3. Parameter list
1. Type of detector
2. Type of flow transmitter
3. Type of signal cable
4. Tag No. (When tag plate is specified)
5. Parameter setting list (When parameter setting is specified)
Company name
: Branch:
Name of the contact person:
TEL:
Measuring fluid:
<Parameter specification table Measurement mode: 1-path/energy measurement>
Setting item
Initial value
Setting value
Setting range
ID No
0000
ID No. is invalid when 0000 is selected.
Language
Japanese
English, Japanese, German, French, Spanish
Measurement mode
1 path
1 path, 2 path, 2 pipes
Calculation output
Average
―
Average, Addition, Sub (CH1-CH2),
Sub (CH2-CH1)
Operation mode
Normal
Normal, High speed
System unit
Metric
Metric or Inch
Flow unit
㎥
/h
L/s, L/min, L/h, L/d, kL/d, ML/d, m
3
/s, m
3
/min, m
3
/h,
m
3
/d, km
3
/d, Mm
3
/d, BBL/s, BBL/min, BBL/h,
BBL/d, kBBL/d, MBBL/d
Total unit
㎥
mL, L, m
3
, km
3
, Mm
3
, mBBL, BBL, kBBL
Temperature unit
℃
℃
, K, F
Thermal unit
MJ/h
MJ/h, GJ/h, BTU/h, kBTU/h, MBTU/h, kWh, MWh
Unit
Total unit (thermal)
MJ
MJ, GJ, BTU, kBTU, MBTU, kW, MW
Outer diameter
60.00mm
6.00 to 6200.00mm
Pipe material
PVC
Carbon steel, Stainless, PVC, Copper, Cast
iron, Aluminum, FRP, Ductile iron, PEEK,
PVDF, Acrylic and PP
Pipe sound velocity
(Sound velocity: [m/s, ft/s])
Wall thickness
4.00mm
4.00mm
Lining material
No lining
No lining, Tar epoxy, Mortar, Rubber, Teflon,
Pyrex glass, PVC
Lining S.V. (Sound velocity: [m/s, ft/s])
Lining thickness
―
0.01 to 100.00mm
Kind of fluid
Water
Water, seawater, dist. water, ammonia, alcohol,
benzene, bromide, ethanol, glycol, kerosene,
milk, methanol, toluol, lube oil, fuel oil, petrol
and refrigerant R410
Fluid S.V. (Sound velocity: [m/s, ft/s])
Viscosity
1.0038×10
-6
㎡
/s
0.001 to 999.999×10
-6
m
2
/s
Sensor mounting method
V method
V method, Z method
Pr
ocess setting
Sensor type
FSSA
FSSA/FSSG,FLS_12/FLS_22,FSSC,FSG_32,
FSG_31/FSG_41,FSSE/FSG_50FSSF/FSG_51,
FSD12,FSSD/FSD22,FSSH/FSD32
Energy mode
Used
Not used, Used
Operation mode
Cooling
Cooling, Heating, Air-conditionning
Thermal coefficient for
cooling
4.186
1.000 to 9.999
Measuring conditions
Energy
measuremet Thermal coefficient for
heating
4.123
1.000 to 9.999
Damping
5.0 sec
0.0 to 100.0sec
Low flow cut
0.15
㎥
/h
0 to 5m/s in terms of flow velocity
Analog output 1 source
channel
CH1
:
Thermal
flow
CH1: Flow rate
,
CH1: Thermal flow
Analog output 2 source
channel
CH1
:
Flow rate
CH1: Flow rate
,
CH1: Thermal flow
Kind
Flow rate
Velocity, Flow rate
Range type
Single
Single, Auto 2, Bi-dir, Bi-dir Auto 2
Full scale 1
15.000
㎥
/h
0, ±0.3 to ±32m/s in terms of flow velocity
Full scale 2
0.000
㎥
/h
0, ±0.3 to ±32m/s in terms of flow velocity
Full scale 1 (thermal)
0.000 MJ/h
0.000000 to 99999999
Full scale 2 (thermal)
0.000 MJ/h
0.000000 to 99999999
Hysteresis
10.00 %
0.00 to 20.00%
Burnout (current)
Hold
Not used, Hold, Lower, Upper and Zero
Burnout timer
10 sec
10 to 900sec
Output condition
s
Analog output
Output limit low
-20 %
-20 to 0%