7-9
7.2.4 Auto Top Off Problems
Problem
Probable Causes
Corrective Action
Frypots won’t top
off.
A.
Auto top off power switch is off.
B.
Pump defective or over tightened.
A.
Verify that the auto top off
power switch is switched on.
The switch is located behind the
JIB on the left side of the auto
top off control box.
B.
Call your FASC.
The yellow JIB low
light won’t
illuminate.
A.
Failed transformer
B.
Three-phase power in the contactor
box left of the JIB is not present.
C.
Loose wire connection
This indicates a problem that is
beyond the scope of operator
troubleshooting. Call your FASC.
One vat tops off but
other vats fail to top
off.
A.
Failed solenoid
This indicates a problem that is
beyond the scope of operator
troubleshooting. Call your FASC.