4-27
Computer displays
fill pot from DRAIN
pan
alternating with
yes no
(see Figure 184).
Figure 184
4. Press the (
1
yes
) button to continue (see Figure
185).
System checks that the drain valve is closed. The return
valve opens and the filter pump refills the vat.
Figure 185 Figure 186
Computer displays
fill vat
while refilling (see Figure 186).
When the vat is full, the return valve is closed. The pump shuts off. The system checks the oil level,
topping off if necessary.
If the oil temperature is below setpoint the computer
displays
low temp
(see Figure 187).
Figure 187
Once fryer reaches setpoint and the computer display
changes to the product or dashed lines, the fryer is ready
for use (see Figure 188).
Figure 188
4.11.4 Fill Pot from Bulk
Fill pot from bulk selection is used when filling the frypot
from a bulk oil system.
Computer displays
OFF
(see Figure 189).
Figure 189
1. Press and hold the filter button for the vat to be refilled
for three seconds (see Figure 190).
Figure 190
Computer displays
filter menu
for three seconds,
changing to
Auto Filter
(see Figure 191).
Figure 191