5-9
5.5
Manual or End of Day Filtration (MAINT FLTR)
NOTICE
The filter pad or paper must be replaced daily.
DANGER
Do not drain more than one frypot at a time into the built-in filtration unit to avoid
overflow and spillage of hot oil that may cause severe burns, slipping and falling.
Ensure that the filter pad or paper is replaced daily to keep the system operating correctly.
1. With the computer
OFF
(see Figure 13) press
and hold the
FLTR
button for three seconds
(see Figure 14).
Figure 13
Figure 14
Computer displays
fltr menu
for three
seconds changing to
Auto Filter
(see
Figure 15).
Figure 15
2. Press the
u
(
INFO
)
button (see Figure 16) to
scroll to
maInT fltr
(see Figure 17).
Figure 16 Figure 17
3. When the desired selection is displayed press
the
9
(
1
yes
) button to continue (see Figure
18).
Figure 18
The screen alternates between
man fltr
and
Yes NO
(see Figure 19).
4. Press the
9
(
1
yes
) button to start the
manual filtration process (see Figure 20).
The heat source is disabled and the system
verifies that the pan is in place.
Figure 19 Figure 20