4-20
Computer displays
filter menu
for three seconds,
changing to
Auto Filter
(see Figure 120).
3. With
Auto Filter
displayed, press the
u
(
INFO
)
button (see Figure 121) to scroll to
dispose
(see
Figure 122).
Computer displays
DISPOSE
(see Figure 122).
4. Press the
(
1
yes
) button to continue (see Figure
123).
The computer display alternates between
Dispose
and
Yes NO
(see Figure 124).
Figure 120
Figure 121
Figure 122 Figure 123
Figure 124 Figure 125
5. To dispose press the
(
1
yes
) button to continue (see
Figure 125).
WARNING
NEVER drain boil-out solution into an MSDU. Boil-out solution can cause damage to
an MSDU.
DANGER
When draining oil into a disposal unit, do not fill above the maximum fill line located
on the container.
DANGER
Allow oil or boil-out solution to cool to 100°F (38°C) before draining into an
appropriate METAL container for disposal.
DANGER
When draining oil or boil-out solution into an appropriate METAL container, make
sure the container will hold at least FOUR gallons (15 liters) or more, otherwise hot
liquid could overflow and cause injury.
The computer display alternates between
is dispose
unit in place
and
Yes NO
(see Figure 126). If
NO
is selected, the computer displays
INSERT
DISPOSAL UNIT
alternating with
IS DISPOSE
UNIT IN PLACE
and
YES NO
.
Figure 126