7-5
Problem
Probable Causes
Corrective Action
M2007 display
shows
REMOVE
DISCARD
.
In non-dedicated mode a product is
dropped that has a different setpoint
than the current vat temperature.
Remove and discard product. Press
and hold the cook button for three
seconds under the display with the
error to remove the error. Reset the
setpoint of the vat before trying to
cook product.
M2007 display
shows
hot-hi-1
.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
This in an indication of a
malfunction in the temperature
control circuitry, including a failure
of the high-limit thermostat. Shut
the fryer down immediately and call
your FASC.
M2007 display
shows
low temp
heating indicator
cycles on and off
normally..
Frypot temperature is between
180°F (82°C) and 315°F (157°C).
This display is normal when the
fryer is first turned on while in the
melt cycle mode. It may appear for a
short while if a large batch of frozen
product is added to the frypot. If the
display never goes out, the fryer is
not heating. Shut the fryer down and
call your FASC.
M2007 display
shows
PROBE
FAILURE.
Problem with the temperature
measuring circuitry including the
probe.
This indicates a problem within the
temperature measuring circuitry that
is beyond the scope of operator
troubleshooting. Shut the fryer
down and call your FASC.
M2007 display
shows
IGNITION
FAILURE.
Open drain valve, failed computer,
failed interface board, open high-
limit thermostat.
This indicates that the fryer is not
heating. It is displayed if the fryer
loses its ability to heat oil. It is also
displayed when the oil temperature is
above 450°F (232°C) and the high-
limit thermostat has opened, halting
the heating of the oil. Verify that the
drain valves are fully closed. If this
does not correct the problem, call
your FASC.
M2007 display
shows
HI-LIMIT.
Computer in high-limit test mode.
This is displayed only during a test
of the high-limit circuit and indicates
that the high-limit has opened
properly.
M2007 display
shows
HI 2 BAD.
Computer in high-limit test mode.
This is displayed only during a test
of the high-limit circuit and indicates
that the high-limit has failed. DO
NOT OPERATE THE FRYER! Call
your FASC.