![Fronius Primo 208-240 Service Manual & Spare Parts List Download Page 99](http://html1.mh-extra.com/html/fronius/primo-208-240/primo-208-240_service-manual-and-spare-parts-list_2339193099.webp)
99
EN-US
Code
Description
Behavior
Remedy
401
Communication error be-
tween the Recerbo and the
power module
1. Ribbon cable between the
power module and filter PC
board faulty or not connected
correctly
1. Check ribbon cable between
Recerbo and the power mod-
ule
2. Ribbon cable faulty
2. Replace ribbon cable
3. Recerbo not connected cor-
rectly
3. Check Recerbo plug
4. Recerbo faulty
4. Replace Recerbo
5. Power module faulty
5. Replace AC power module
6. Filter PC board faulty
6. Replace filter PC board
406
Temperature sensor in the
DC semiconductor module
faulty
1. Faulty temperature sensor in
the semiconductor module
1. Replace DC PC board
2. Faulty circuit on power mod-
ule
2. Replace DC PC board
407
Temperature sensor on
power module faulty
1. Faulty temperature sensor
on power module
1. Replace AC PC board
2. Faulty circuit on power mod-
ule
2. Replace AC PC board
408
Unacceptably high DC de-
celeration detected on in-
verter
1. Asynchronous alternating
current grid
1. Check alternating current
grid
2. Power module faulty
2. Replace AC PC board
412
Set fixed voltage outside of
permissible MPP range
1. Fixed voltage set too high or
too low
1. Check adjustments in ser-
vice menu
415
Release signal: option
cards triggered
1. Option card does not pro-
vide release for feeding energy
into the grid
1. Automatically corrected; op-
tion card stopped inverter
416–425
Communication between
power module and Recerbo
not possible
1. Occurs once – PSP commu-
nication error
1. Automatically corrected
2. Unknown option card is
blocking inverter
2. Software update
3. Ribbon cable between filter
PC board and power module
faulty
3. Replace ribbon cable
4. Recerbo faulty
4. Replace Recerbo
5. Filter PC board faulty
5. Replace filter PC board
6. Power module faulty
6. Replace AC PC board
426
Intermediate circuit
charging takes too long
1. DC voltage too weak
1. Restart inverter or check ca-
bling
2. DC inductor not cleanly con-
tacted
2. Check cabling of the DC in-
ductor
3. DC booster faulty
3. Replace DC PC board and
then, if necessary, AC PC
board
427
Power module inoperative
for too long (timeout)
1. Software fault
1. Software update
2. Measurement error on pow-
er module
2. Replace AC PC board
Summary of Contents for Primo 208-240
Page 2: ...2...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 14: ...14...
Page 15: ...Fehler Suchhilfe...
Page 16: ......
Page 34: ...34...
Page 35: ...Komponenten austauschen...
Page 36: ......
Page 55: ...55 DE DC Trenner auf ON stellen 6...
Page 66: ...66...
Page 67: ...Sicherheitstechnische berpr fung...
Page 68: ......
Page 80: ...80...
Page 83: ...General Information...
Page 84: ......
Page 92: ...92...
Page 93: ...Troubleshooting guide...
Page 94: ......
Page 112: ...112...
Page 113: ...Replacing components...
Page 114: ......
Page 133: ...133 EN US Set the DC disconnector to ON 6...
Page 144: ...144...
Page 145: ...Safety inspection...
Page 146: ......
Page 158: ...158...
Page 159: ...Appendix...
Page 162: ...162...
Page 163: ...163...