102
462
Error detected when moni-
toring DC deceleration
1. Occurs once
1. Restart inverter
2. Monitoring of DC decelera-
tion faulty
2. Replace inverter
463
AC pole reserved
1. AC connection between
power module and filter PC
board established in incorrect
direction (L1 and L2 mixed up)
1. Check cabling
472
Fuse for solar module
ground faulty
1. Faulty fuse for solar module
ground
1. Replace fuse
2. Incorrect setting in basic ser-
vice menu
2. Set DC mode to "floating"
474
RCMU sensor fault
1. Quick irradiation change
1. Automatically corrected
2. Sensor faulty
2. Replace filter PC board
475
Insulation fault detected
1. Incorrect setting
1. Check ISO/GFDI setting
2. Grounding fault PV genera-
tor
2. Check PV generator
3. Measurement circuit on
power module defective
3. Replace DC PC board and
then, if necessary, AC PC
board
476
Internal power supply miss-
ing
1. Grid voltage too low
1. Check cabling
2. Grid test time is too low
2. Grid failure
3. Missing internal power sup-
ply
3. Replace AC PC board
4. Missing internal power sup-
ply
4. Replace filter PC board
480
Power module and display
software incompatible
1. Old power module/display
software
1. Software update
2. Old software
2. Reload setup
3. Incompatible hardware com-
bination
3. Check hardware compo-
nents
481
Recerbo has old software
version
1. Old Recerbo software
1. Software update
2. Old software
2. Reload setup
3. Incompatible hardware com-
bination
3. Check hardware compo-
nents
482
Inverter switched off during
commissioning
1. Startup process not suc-
cessful
1. Restart inverter
483
Set DC2 fixed voltage out-
side of the permitted MPP
range
1. Incorrectly set fixed voltage
1. Check settings
484–485
Error during data transfer
1. Communication problem
caused by temporary environ-
mental faults (grid, EMC, etc.)
1. Automatically corrected
2. Ribbon cable between filter
PC board and power module
faulty
2. Replace ribbon cable
3. Faulty AC guard on filter PC
board
3. Replace filter PC board
4. Faulty AC guard on power
module
4. Replace AC PC board
Code
Description
Behavior
Remedy
Summary of Contents for Primo 208-240
Page 2: ...2...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 14: ...14...
Page 15: ...Fehler Suchhilfe...
Page 16: ......
Page 34: ...34...
Page 35: ...Komponenten austauschen...
Page 36: ......
Page 55: ...55 DE DC Trenner auf ON stellen 6...
Page 66: ...66...
Page 67: ...Sicherheitstechnische berpr fung...
Page 68: ......
Page 80: ...80...
Page 83: ...General Information...
Page 84: ......
Page 92: ...92...
Page 93: ...Troubleshooting guide...
Page 94: ......
Page 112: ...112...
Page 113: ...Replacing components...
Page 114: ......
Page 133: ...133 EN US Set the DC disconnector to ON 6...
Page 144: ...144...
Page 145: ...Safety inspection...
Page 146: ......
Page 158: ...158...
Page 159: ...Appendix...
Page 162: ...162...
Page 163: ...163...