Class 4 Service
Codes
Class 4 status codes may require the intervention of a trained Fronius service technician.
303
Heat sink temperature too
high
1. Ventilation opening blocked
1. Clean openings
2. Ambient temperature too
high
2. Change setup location
3. Internal or external fans not
connected
3. Connect fan cable
4. Internal or external fans
faulty
4. Replace fans
5. Bad contact: power module
<--> heat sink
5. Check phase change paste
6. Measurement error on pow-
er module
6. Replace AC PC board
7. Ventilator power on Recerbo
faulty
7. Replace Recerbo
306
POWER LOW
1. DC power too low for infeed
1. Wait for more radiation in-
tensity or check solar modules
2. Measurement error on pow-
er module
2. Replace DC PC board. Oth-
erwise replace AC PC board
307
DC LOW
1. Open the main DC switch.
1. Close the main DC switch.
2. PV generator not connected
2. Connect PV generator
3. DC voltage too low for infeed
3. Wait for more radiation in-
tensity or check solar modules
4. Reverse voltage of PV gen-
erator
4. Reverse polarity of PV gen-
erator
5. DC operating mode: fixed
v incorrect voltage
5. Check MPP settings/voltag-
es
6. Measurement error on pow-
er module
6. Replace DC PC board. Oth-
erwise replace AC PC board
308
The intermediate circuit
voltage exceeds max. per-
missible limit
1. Voltage drop in alternating
current grid
1. Automatic correction
2. Bad contact: wall bracket <-
-> inverter
2. Check fixing screws in DAT-
COM area
3. Measurement error on pow-
er module
3. Replace AC PC board
309
DC1 voltage too high
1. PV generator voltage at
MPP 1 too high
1. Check PV configuration
2. Incorrect DC cabling at MPP
1
2. Check DC cabling
3. Measurement error on pow-
er module
3. Replace DC PC board. Oth-
erwise replace AC PC board
313
DC2 voltage too high
1. PV generator voltage at
MPP 2 too high
1. Check PV configuration
2. Incorrect DC cabling at MPP
2
2. Check DC cabling
3. Measurement error on pow-
er module
3. Replace DC PC board. Oth-
erwise replace AC PC board
Code
Description
Behavior
Remedy
Summary of Contents for Primo 208-240
Page 2: ...2...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 14: ...14...
Page 15: ...Fehler Suchhilfe...
Page 16: ......
Page 34: ...34...
Page 35: ...Komponenten austauschen...
Page 36: ......
Page 55: ...55 DE DC Trenner auf ON stellen 6...
Page 66: ...66...
Page 67: ...Sicherheitstechnische berpr fung...
Page 68: ......
Page 80: ...80...
Page 83: ...General Information...
Page 84: ......
Page 92: ...92...
Page 93: ...Troubleshooting guide...
Page 94: ......
Page 112: ...112...
Page 113: ...Replacing components...
Page 114: ......
Page 133: ...133 EN US Set the DC disconnector to ON 6...
Page 144: ...144...
Page 145: ...Safety inspection...
Page 146: ......
Page 158: ...158...
Page 159: ...Appendix...
Page 162: ...162...
Page 163: ...163...