108
772
Memory on memory PC
board cannot be accessed;
inverter infeed is deactivat-
ed for safety reasons
1. SSP not connected
1. Check SSP
773
Memory on memory PC
board not initialized; invert-
er infeed is deactivated for
safety reasons
1. Memory not programmed or
memory lost
1. Reload setup
2. Faulty Recerbo
2. Replace Recerbo
775
Incorrect programming of
power module
1. Power module or filter PC
board not programmed
1. See device -> info menu:
Search for missing version info
and replace faulty PC board
782*–783*
Error during update
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
784*
Wait for memory allocation
1. Occurs once
1. Automatically corrected
2. Recerbo faulty
2. Replace Recerbo
789*
Setup CRC failed
1. Faulty file in the memory
1. Update software
2. Recerbo faulty
2. Replace Recerbo
794*
Memory structure damaged
1. Faulty file in the memory
1. Update software
2. Recerbo faulty
2. Replace Recerbo
901
Measuring error channel 1
Current from channel 1 is dif-
ferent from the others
Check settings, DC fuses and
modules
902
Measuring error channel 2
Current from channel 2 is dif-
ferent from the others
Check settings, DC fuses and
modules
903
Measuring error channel 3
Current from channel 3 is dif-
ferent from the others
Check settings, DC fuses and
modules
904
Measuring error channel 4
Current from channel 4 is dif-
ferent from the others
Check settings, DC fuses and
modules
905
Measuring error channel 5
Current from channel 5 is dif-
ferent from the others
Check settings, DC fuses and
modules
990
Discrepancy in the return of
the value from the irradia-
tion sensor too large
Difference between power of
the irradiation sensor and the
power of the inverter is too
large
Check archive values, shad-
owing, string fuse and for faulty
modules
991
Discrepancy in the irradia-
tion sensor too large
Discrepancy in the irradiation
sensor too large
Check whether the irradiation
sensor is dirty, in shadow or
faulty
992
No values from the irradia-
tion sensor, or value(s) not
permitted
Irradiation sensor provides no
values or inadmissible values
Check cabling of the irradiation
sensor
993
Energy report faulty
Archive values missing
Check archive values in the
Fronius Solar.web server or
Datalogger
996
No connection to the Fro-
nius Solar.web
No connection to the Fronius
Solar.web
1. Check LED status on the
Datalogger
2. Restart Datalogger
3. Check Internet connection
4. Check whether customer
has a timer to switch off the In-
ternet connection and the time
interval setting is too short.
Code
Description
Behavior
Remedy
Summary of Contents for Primo 208-240
Page 2: ...2...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 14: ...14...
Page 15: ...Fehler Suchhilfe...
Page 16: ......
Page 34: ...34...
Page 35: ...Komponenten austauschen...
Page 36: ......
Page 55: ...55 DE DC Trenner auf ON stellen 6...
Page 66: ...66...
Page 67: ...Sicherheitstechnische berpr fung...
Page 68: ......
Page 80: ...80...
Page 83: ...General Information...
Page 84: ......
Page 92: ...92...
Page 93: ...Troubleshooting guide...
Page 94: ......
Page 112: ...112...
Page 113: ...Replacing components...
Page 114: ......
Page 133: ...133 EN US Set the DC disconnector to ON 6...
Page 144: ...144...
Page 145: ...Safety inspection...
Page 146: ......
Page 158: ...158...
Page 159: ...Appendix...
Page 162: ...162...
Page 163: ...163...