Ground conductor current
-
The effective inner resistance of the ground conductor current measuring device may
be a maximum of 5
. (With higher resistances, measures must be taken to prevent
the occurrence of hazardous contact voltages.)
-
The measuring range must comprise at least the values from 0.25 mA to 19 mA.
-
The inspection facility must assess the measured current to be an effective value re-
gardless of the waveform.
Contact Current
-
The effective inner resistance of the contact current measurement instrument must be
1 k
to 2 k
.
-
If the current test circuit is accidentally connected to a voltage up to 120% of the nom-
inal grid voltage, the user must not be endangered and the test circuit must not be
damaged.
-
The inspection facility must assess the measured current to be an effective value re-
gardless of the waveform.
Summary of Contents for Primo 208-240
Page 2: ...2...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 14: ...14...
Page 15: ...Fehler Suchhilfe...
Page 16: ......
Page 34: ...34...
Page 35: ...Komponenten austauschen...
Page 36: ......
Page 55: ...55 DE DC Trenner auf ON stellen 6...
Page 66: ...66...
Page 67: ...Sicherheitstechnische berpr fung...
Page 68: ......
Page 80: ...80...
Page 83: ...General Information...
Page 84: ......
Page 92: ...92...
Page 93: ...Troubleshooting guide...
Page 94: ......
Page 112: ...112...
Page 113: ...Replacing components...
Page 114: ......
Page 133: ...133 EN US Set the DC disconnector to ON 6...
Page 144: ...144...
Page 145: ...Safety inspection...
Page 146: ......
Page 158: ...158...
Page 159: ...Appendix...
Page 162: ...162...
Page 163: ...163...