Visual inspection
General
During a visual inspection, the tests described below are to be carried out without further
dismantling of the equipment. Safety related parts must not show any visible defects. Fur-
thermore, defects which may present a danger during the visual inspection must be written
down.
Deficiencies identified that may be the cause of other hazards must be repaired immedi-
ately, otherwise further use must be restricted until the defect is rectified.
Mains Power Sup-
ply and Connec-
tion Cables
-
Connection cables and external leads must not be damaged or defective.
-
Insulation must not be defective (do not use insulation or adhesive tape to repair dam-
age).
-
Plugs and plug connections must not be damaged or deformed.
-
Strain relief devices, bend radius protection devices, conduits and fixings must be ef-
fective.
-
Cables/plugs must be suitable for their area of application and power.
-
Fuse links and device fuse holders must not be defective.
Housing and Cov-
ers
-
Housing, insulation items and protective covers must not be missing or damaged.
-
Unauthorized modifications must not be present, e.g.: Fittings and modifications not
authorized by the manufacturer.
-
Ventilation openings must not be soiled or blocked, air filters must be present.
-
There must be no sign of soiling, corrosion or degradation that would compromise
safety.
-
Indications of overload and improper use must not be present.
-
Conductive objects must not be inside the housing.
Adjustment and
display devices
-
Control elements and indicators must not be faulty
Rating Plate and
Warning Stickers
-
Safety-related labels must be present, e.g.: Warning notices, grounding symbols, and
rating plates. If necessary, renew, add to or correct the labels in a suitable form.
-
Ensure that all safety-related labels or symbols, rated values and position indicators
are legible.
IMPORTANT!
To determine the cross-section and current carrying capacity of mains ca-
bles, observe standard IEC 60364-5-52. As the current carrying capacity can vary due to
the cable layout and its insulation and differing ambient temperatures, when the mains
leads are replaced the requirements of standard IEC 60364-5-52 must be met. Individual
national requirements and standards must also be observed.
Summary of Contents for Primo 208-240
Page 2: ...2...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 14: ...14...
Page 15: ...Fehler Suchhilfe...
Page 16: ......
Page 34: ...34...
Page 35: ...Komponenten austauschen...
Page 36: ......
Page 55: ...55 DE DC Trenner auf ON stellen 6...
Page 66: ...66...
Page 67: ...Sicherheitstechnische berpr fung...
Page 68: ......
Page 80: ...80...
Page 83: ...General Information...
Page 84: ......
Page 92: ...92...
Page 93: ...Troubleshooting guide...
Page 94: ......
Page 112: ...112...
Page 113: ...Replacing components...
Page 114: ......
Page 133: ...133 EN US Set the DC disconnector to ON 6...
Page 144: ...144...
Page 145: ...Safety inspection...
Page 146: ......
Page 158: ...158...
Page 159: ...Appendix...
Page 162: ...162...
Page 163: ...163...