10
Proper use
Environmental
conditions
Obligations of the
operator
The LaserHybrid head is to be used exclusively for its intended purpose.
The LaserHybrid head is intended solely for use in LaserHybrid welding of al-
uminium, CrNi and steel materials.
Any use above and beyond this purpose is deemed improper.
The manufacturer shall not be held liable for any damage arising from such
usage.
Proper use also includes:
-
carefully reading and following all the instructions given in the operating
instructions
-
studying and obeying all safety and danger notices carefully
-
performing all stipulated inspection and servicing work.
Never attempt to use the LaserHybrid head or the power source being used
for thawing frozen pipes.
The LaserHybrid head is designed for use in industry and the workshop. The
manufacturer accepts no responsibility for any damage caused through use in
a domestic setting.
The manufacturer likewise accepts no liability for inadequate or incorrect work
results.
Operation or storage of the LaserHybrid head outside the stipulated area will
be deemed as not in accordance with the intended purpose. The manufacturer
shall not be held liable for any damage arising from such usage.
Ambient air temperature range:
-
during operation: -10 °C to + 40 °C (14 °F to 104 °F)
-
during transport and storage: -25 °C to + 55 °C (-13 °F to 131 °F)
Relative humidity:
-
up to 50% at 40 °C (104 °F)
-
up to 90% at 20 °C (68 °F)
The ambient air must be free from dust, acids, corrosive gases or substances,
etc.
Can be used at altitudes up to 2000 m (6561 ft. 8.16 in.)
The operator must only allow persons to work with the LaserHybrid head who:
-
are familiar with the fundamental instructions regarding safety at work and
accident prevention and have been instructed in how to use the LaserHy-
brid head
-
have read and understood these operating instructions, especially the
"Safety rules" section, and have confirmed as much with their signatures
-
are trained to produce the required results.
Checks must be carried out at regular intervals to ensure that operators are
working in a safety-conscious manner.
Summary of Contents for LaserHybrid Ultracompact Twin
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 18: ...18...
Page 19: ...General information...
Page 20: ......
Page 34: ...34...
Page 35: ...Control elements and connections...
Page 36: ......
Page 41: ...Start up...
Page 42: ......
Page 76: ...76...
Page 77: ...Maintenance...
Page 78: ......
Page 94: ...94 3 Position the gas nozzle and secure using a 2 5 mm Al len key Tightening torque 1 Nm 5...
Page 96: ...96 Fit the spatter guard plate using two Al len screws 3 mm 2 2 2...
Page 110: ...110...
Page 111: ...Appendix...
Page 112: ......
Page 114: ...114 Spare parts list LaserHybrid Ultracompact Twin...
Page 115: ...115...
Page 116: ...116...
Page 118: ...118...
Page 119: ...119...