48
PB
TROUBLESHOOTING
Diagnostic Codes
Indoor Unit
Error
Code
Power Timer
Running Sleep
1
2
3
4
Content
The root cause is may be one of the following
23
1. The wiring of the sensor
for the expansion valve A
(thin tube) connect loose;
2. The sensor for the
expansion A(thin tube) has
failure;
3. The sampling circuit is
abnormal.
24
Outdoor board chip failure.
a.Using the wrong drive board;
b.Using the wrong compressor
26
Overheated outdoor
radiator
a. Radiator sensor fails.
b. Detection circuit of the sensor on the
control panel fails.
27
Protection against too high
system pressure
a. The pressure switch fails.
b. The pressure detection switch on the
control panel fails.
c. The measured value of system pressure
exceeds the limit.
33
BLINK
OFF
OFF
ON
The failure for temperature
sensor of indoor room
a. The indoor room temperature sensor loose.
b. The indoor room temperature sensor failed.
c. The indoor control board failed.
34
BLINK
OFF
ON
OFF
The failure for temperature
sensor of indoor coil
temperature
a. The indoor coil temperature sensor loose.
b. The indoor coil temperature sensor failed.
c. The indoor control board failed.
36
BLINK
ON
OFF
ON
Communication failure
between the indoor unit
and outdoor unit
a. the communication cable connector loose.
b. the connection between the filter board
and the terminal is incorrect or loose.
c. the communication cable failed.
d. the connection between the filter board and
the outdoor control board is incorrect or loose.
e. the indoor control board failed.
f. the PFC board failed.
g. the power board failed.
h. the outdoor control board failed.
38
BLINK
ON
ON
ON
Indoor EEPROM failure
a. The EEPROM chip loose;
b. The indoor control board failed.
39
BLINK
OFF
ON
ON
Indoor fan motor runs
abnormally.
a. Something blocking the indoor fan motor.
b. The fan motor cord is disconnected or
loose.
c. The fan motor failed.
d. The indoor control board failed.
41
ON
ON
BLINK
ON
The failure for Indoor
grounding protection.
The indoor control board failed.
77
ON
WiFi Connection Enabled
Cycle Power on/off
Summary of Contents for Floating Air Pro-Premiere FPHFW18A3A
Page 25: ...25 INSTALLATION Installation Dimension Diagram Figure 401 ...
Page 26: ...26 INSTALLATION Main Tools For Installation and Maintenance Figure 402 ...
Page 34: ...34 INSTALLATION Install Outdoor Unit Fig 431 ...
Page 35: ...35 INSTALLATION Outdoor Units ...
Page 40: ...40 MAINTENANCE Fig 501 ...
Page 59: ...59 TROUBLESHOOTING Error Code 13 Fig 708 Error Code 8 ...
Page 62: ...62 TROUBLESHOOTING Error Code 20 DC fan motor test point Fig 711 ...
Page 68: ...68 Fig 716 TROUBLESHOOTING Error Code 36 ...
Page 73: ...73 COMPONENTS TESTING Fan Motor ...
Page 87: ...87 WIRING DIAGRAMS Outdoor Units Figure 805 9 36K Outdoor Units ...